Masmaria Abdul Majid, Z. Janin, Abdul Hapiz Mohd Taib, M. Taib
{"title":"过阻尼过程响应的温度控制调谐","authors":"Masmaria Abdul Majid, Z. Janin, Abdul Hapiz Mohd Taib, M. Taib","doi":"10.1109/CSPA.2009.5069267","DOIUrl":null,"url":null,"abstract":"The main objective of this study is to determine the optimum tuning of temperature process control for overdamped process response. The Ziegler Nichols tuning was used to determine the optimum setting of temperature process control in 30°C – 50°C by varying the PB and I term. The performance of the response is evaluated based on integral absolute error (IAE), settling time (Ts), and rise time (Tr), first overshoot and undershoot.","PeriodicalId":338469,"journal":{"name":"2009 5th International Colloquium on Signal Processing & Its Applications","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Temperature control tuning for overdamped process response\",\"authors\":\"Masmaria Abdul Majid, Z. Janin, Abdul Hapiz Mohd Taib, M. Taib\",\"doi\":\"10.1109/CSPA.2009.5069267\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main objective of this study is to determine the optimum tuning of temperature process control for overdamped process response. The Ziegler Nichols tuning was used to determine the optimum setting of temperature process control in 30°C – 50°C by varying the PB and I term. The performance of the response is evaluated based on integral absolute error (IAE), settling time (Ts), and rise time (Tr), first overshoot and undershoot.\",\"PeriodicalId\":338469,\"journal\":{\"name\":\"2009 5th International Colloquium on Signal Processing & Its Applications\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-03-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 5th International Colloquium on Signal Processing & Its Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CSPA.2009.5069267\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 5th International Colloquium on Signal Processing & Its Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CSPA.2009.5069267","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Temperature control tuning for overdamped process response
The main objective of this study is to determine the optimum tuning of temperature process control for overdamped process response. The Ziegler Nichols tuning was used to determine the optimum setting of temperature process control in 30°C – 50°C by varying the PB and I term. The performance of the response is evaluated based on integral absolute error (IAE), settling time (Ts), and rise time (Tr), first overshoot and undershoot.