{"title":"涡流位移传感中的目标温度效应","authors":"D. Vyroubal, I. Lacković","doi":"10.1109/SAS.2015.7133621","DOIUrl":null,"url":null,"abstract":"Target temperature effect on eddy current displacement sensing is analyzed and evaluated by simulation. The equivalent target quality factor is detected as the main factor that, along with the probe equivalent quality factor, determines this effect. It manifests in ambiguity of displacement measurement, as well as, masking the displacement variation by target temperature variation, and vice versa. The analysis and the simulation show that there is an optimal operating frequency for minimum sensitivity over an acceptable displacement range.","PeriodicalId":384041,"journal":{"name":"2015 IEEE Sensors Applications Symposium (SAS)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Target temperature effect on eddy-current displacement sensing\",\"authors\":\"D. Vyroubal, I. Lacković\",\"doi\":\"10.1109/SAS.2015.7133621\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Target temperature effect on eddy current displacement sensing is analyzed and evaluated by simulation. The equivalent target quality factor is detected as the main factor that, along with the probe equivalent quality factor, determines this effect. It manifests in ambiguity of displacement measurement, as well as, masking the displacement variation by target temperature variation, and vice versa. The analysis and the simulation show that there is an optimal operating frequency for minimum sensitivity over an acceptable displacement range.\",\"PeriodicalId\":384041,\"journal\":{\"name\":\"2015 IEEE Sensors Applications Symposium (SAS)\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Sensors Applications Symposium (SAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SAS.2015.7133621\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Sensors Applications Symposium (SAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SAS.2015.7133621","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Target temperature effect on eddy-current displacement sensing
Target temperature effect on eddy current displacement sensing is analyzed and evaluated by simulation. The equivalent target quality factor is detected as the main factor that, along with the probe equivalent quality factor, determines this effect. It manifests in ambiguity of displacement measurement, as well as, masking the displacement variation by target temperature variation, and vice versa. The analysis and the simulation show that there is an optimal operating frequency for minimum sensitivity over an acceptable displacement range.