热像仪检测旁路激活二极管对光伏板现场性能的影响

Alexandru-Ionel Constantin, D. Marin, P. Anghelita, Ioan Tiberiu Şerban, C. Morari, Gabriela Iosif
{"title":"热像仪检测旁路激活二极管对光伏板现场性能的影响","authors":"Alexandru-Ionel Constantin, D. Marin, P. Anghelita, Ioan Tiberiu Şerban, C. Morari, Gabriela Iosif","doi":"10.1109/ATEE58038.2023.10108146","DOIUrl":null,"url":null,"abstract":"The paper presents results related to photovoltaic (PV) panels performances evaluation on bypass activated diodes faults, detected by means of thermographic inspection using two thermal cameras, as part of a preventive maintenance process on 8 years old on-grid 12 kW peak power system roof top, installed at National Institute for Research and Development in Electrical Engineering ICPE-CA. The PV panels performance evaluation is based on comparison of the faulty PV panels that contains bypass activated diodes with healthy ones, using their Current-Voltage (I-V) and Power-Voltage (P-V) characteristics measured by means of the HT I-V 400 equipment.","PeriodicalId":398894,"journal":{"name":"2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On-site Performances Evaluation of Photovoltaic Panels Affected by Bypass Activated Diodes Detected with Thermal Cameras\",\"authors\":\"Alexandru-Ionel Constantin, D. Marin, P. Anghelita, Ioan Tiberiu Şerban, C. Morari, Gabriela Iosif\",\"doi\":\"10.1109/ATEE58038.2023.10108146\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents results related to photovoltaic (PV) panels performances evaluation on bypass activated diodes faults, detected by means of thermographic inspection using two thermal cameras, as part of a preventive maintenance process on 8 years old on-grid 12 kW peak power system roof top, installed at National Institute for Research and Development in Electrical Engineering ICPE-CA. The PV panels performance evaluation is based on comparison of the faulty PV panels that contains bypass activated diodes with healthy ones, using their Current-Voltage (I-V) and Power-Voltage (P-V) characteristics measured by means of the HT I-V 400 equipment.\",\"PeriodicalId\":398894,\"journal\":{\"name\":\"2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE)\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ATEE58038.2023.10108146\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 13th International Symposium on Advanced Topics in Electrical Engineering (ATEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ATEE58038.2023.10108146","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了与旁路激活二极管故障的光伏(PV)面板性能评估相关的结果,通过使用两台热像仪进行热成像检测,作为对安装在国家电气工程研究与发展研究所(ICPE-CA)的8年并网12kw峰值电力系统屋顶进行预防性维护过程的一部分。光伏板的性能评估是基于使用HT I-V 400设备测量的电流电压(I-V)和功率电压(P-V)特性,将含有旁路激活二极管的故障光伏板与健康光伏板进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On-site Performances Evaluation of Photovoltaic Panels Affected by Bypass Activated Diodes Detected with Thermal Cameras
The paper presents results related to photovoltaic (PV) panels performances evaluation on bypass activated diodes faults, detected by means of thermographic inspection using two thermal cameras, as part of a preventive maintenance process on 8 years old on-grid 12 kW peak power system roof top, installed at National Institute for Research and Development in Electrical Engineering ICPE-CA. The PV panels performance evaluation is based on comparison of the faulty PV panels that contains bypass activated diodes with healthy ones, using their Current-Voltage (I-V) and Power-Voltage (P-V) characteristics measured by means of the HT I-V 400 equipment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信