基于氧化铱膜的集成pH和钠传感器阵列

Xuesong Yang, J. Chiao
{"title":"基于氧化铱膜的集成pH和钠传感器阵列","authors":"Xuesong Yang, J. Chiao","doi":"10.1109/ICSENS.2018.8589685","DOIUrl":null,"url":null,"abstract":"We have developed a sensor array consisting of an iridium oxide (IrOx) electrode for pH measurement, an iridium oxide based ion-selective sensor for sodium detection, and two silver chloride (AgCl) reference electrodes. The planar sensor array was fabricated on a flexible substrate with simple fabrication processes. The iridium oxide sensing film was synthesized by the sol-gel process. The sodium sensor was fabricated by deposition of a sodium-selective membrane on the iridium oxide film. The silver chloride reference electrodes were made by printing. The sensor array was tested in standard pH buffer solutions with or without the existence of sodium. In both scenarios, a promising sensitivity of 61.46 mV/pH in the pH ranges from acid to alkaline at the room temperature was achieved. The potential increases induced by the sodium interference were calibrated by the sodium sensor. The calibrated results show excellent pH responses with minimum interference. The pH and sodium sensor array demonstrates a unique capability to provide accurate pH detection in the environment containing sodium interference.","PeriodicalId":405874,"journal":{"name":"2018 IEEE SENSORS","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Integrated pH and Sodium Sensor Array Based on Iridium Oxide Film\",\"authors\":\"Xuesong Yang, J. Chiao\",\"doi\":\"10.1109/ICSENS.2018.8589685\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have developed a sensor array consisting of an iridium oxide (IrOx) electrode for pH measurement, an iridium oxide based ion-selective sensor for sodium detection, and two silver chloride (AgCl) reference electrodes. The planar sensor array was fabricated on a flexible substrate with simple fabrication processes. The iridium oxide sensing film was synthesized by the sol-gel process. The sodium sensor was fabricated by deposition of a sodium-selective membrane on the iridium oxide film. The silver chloride reference electrodes were made by printing. The sensor array was tested in standard pH buffer solutions with or without the existence of sodium. In both scenarios, a promising sensitivity of 61.46 mV/pH in the pH ranges from acid to alkaline at the room temperature was achieved. The potential increases induced by the sodium interference were calibrated by the sodium sensor. The calibrated results show excellent pH responses with minimum interference. The pH and sodium sensor array demonstrates a unique capability to provide accurate pH detection in the environment containing sodium interference.\",\"PeriodicalId\":405874,\"journal\":{\"name\":\"2018 IEEE SENSORS\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE SENSORS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2018.8589685\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE SENSORS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2018.8589685","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

我们开发了一种传感器阵列,包括用于pH测量的氧化铱(IrOx)电极,用于钠检测的氧化铱离子选择性传感器和两个氯化银(AgCl)参考电极。采用简单的制作工艺,在柔性衬底上制作了平面传感器阵列。采用溶胶-凝胶法制备了氧化铱传感膜。采用在氧化铱膜上沉积钠选择性膜的方法制备了钠传感器。采用印刷法制备氯化银参比电极。传感器阵列在标准pH缓冲溶液中进行了测试,有或没有钠的存在。在这两种情况下,室温下从酸性到碱性的pH范围内的灵敏度都达到了61.46 mV/pH。用钠传感器标定了钠干扰引起的电位增加。校准结果表明,pH响应良好,干扰最小。pH和钠传感器阵列展示了在含有钠干扰的环境中提供准确pH检测的独特能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Integrated pH and Sodium Sensor Array Based on Iridium Oxide Film
We have developed a sensor array consisting of an iridium oxide (IrOx) electrode for pH measurement, an iridium oxide based ion-selective sensor for sodium detection, and two silver chloride (AgCl) reference electrodes. The planar sensor array was fabricated on a flexible substrate with simple fabrication processes. The iridium oxide sensing film was synthesized by the sol-gel process. The sodium sensor was fabricated by deposition of a sodium-selective membrane on the iridium oxide film. The silver chloride reference electrodes were made by printing. The sensor array was tested in standard pH buffer solutions with or without the existence of sodium. In both scenarios, a promising sensitivity of 61.46 mV/pH in the pH ranges from acid to alkaline at the room temperature was achieved. The potential increases induced by the sodium interference were calibrated by the sodium sensor. The calibrated results show excellent pH responses with minimum interference. The pH and sodium sensor array demonstrates a unique capability to provide accurate pH detection in the environment containing sodium interference.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信