在早期运行电机220 kW时使用软启动方法的有效性分析

Andi Junaidi, Susana Damayanti
{"title":"在早期运行电机220 kW时使用软启动方法的有效性分析","authors":"Andi Junaidi, Susana Damayanti","doi":"10.33322/energi.v11i2.559","DOIUrl":null,"url":null,"abstract":"The  Multipurpose  Reactor  G.A  Siwabessy is a  research reactor equipped with a  Cooling  System consisting of 2 systems, namely the primary cooling system and the secondary cooling system. This Project discusses the effectiveness of using the Soft starter method in the initial starting process of the electric motor in the secondary cooling system which aims to reduce the value of a high current surge when the motor starts working. The data type used is primary data obtained directly by the author through a  measurement process with a  measuring instrument.  When using  the  Star-Delta method the surge current is 765 A while with the Soft starter method there is a decrease in the current surge value to 517 A, the conclusion of the result is a decrease in the current surge value of 0,677% using the Soft starter method \n.","PeriodicalId":377082,"journal":{"name":"Energi & Kelistrikan","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Analisis Efektifitas Penggunaan Metode Soft Starter saat Start awal pada pengoperasian Motor 220 kW\",\"authors\":\"Andi Junaidi, Susana Damayanti\",\"doi\":\"10.33322/energi.v11i2.559\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The  Multipurpose  Reactor  G.A  Siwabessy is a  research reactor equipped with a  Cooling  System consisting of 2 systems, namely the primary cooling system and the secondary cooling system. This Project discusses the effectiveness of using the Soft starter method in the initial starting process of the electric motor in the secondary cooling system which aims to reduce the value of a high current surge when the motor starts working. The data type used is primary data obtained directly by the author through a  measurement process with a  measuring instrument.  When using  the  Star-Delta method the surge current is 765 A while with the Soft starter method there is a decrease in the current surge value to 517 A, the conclusion of the result is a decrease in the current surge value of 0,677% using the Soft starter method \\n.\",\"PeriodicalId\":377082,\"journal\":{\"name\":\"Energi & Kelistrikan\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energi & Kelistrikan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33322/energi.v11i2.559\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energi & Kelistrikan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33322/energi.v11i2.559","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

G.A Siwabessy多用途反应堆是一种研究用反应堆,其冷却系统由两个系统组成,即一次冷却系统和二次冷却系统。本项目探讨了在二冷系统中电动机初始启动过程中采用软启动方法的有效性,旨在降低电动机启动工作时的大电流浪涌值。使用的数据类型是作者通过测量仪器的测量过程直接获得的原始数据。当采用Star-Delta法时,浪涌电流为765 A,而采用软启动法时,浪涌电流值降低到517 A,结论是采用软启动法时,浪涌电流值降低了0.0677%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analisis Efektifitas Penggunaan Metode Soft Starter saat Start awal pada pengoperasian Motor 220 kW
The  Multipurpose  Reactor  G.A  Siwabessy is a  research reactor equipped with a  Cooling  System consisting of 2 systems, namely the primary cooling system and the secondary cooling system. This Project discusses the effectiveness of using the Soft starter method in the initial starting process of the electric motor in the secondary cooling system which aims to reduce the value of a high current surge when the motor starts working. The data type used is primary data obtained directly by the author through a  measurement process with a  measuring instrument.  When using  the  Star-Delta method the surge current is 765 A while with the Soft starter method there is a decrease in the current surge value to 517 A, the conclusion of the result is a decrease in the current surge value of 0,677% using the Soft starter method .
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信