220kv变电站120mvar可变并联电抗器暂态开关研究

Ayyaj S Maner, Amol Salunkhe, Raiju Hassan, Sonu Karekar, Mahesh Ambardekar, Arvindkumar Sharma
{"title":"220kv变电站120mvar可变并联电抗器暂态开关研究","authors":"Ayyaj S Maner, Amol Salunkhe, Raiju Hassan, Sonu Karekar, Mahesh Ambardekar, Arvindkumar Sharma","doi":"10.1109/CISES54857.2022.9844359","DOIUrl":null,"url":null,"abstract":"This paper describes transients switching study carried out for variable shunt reactor (VSR) connected to 220 kV Grid at 220/33 kV Adani Electricity Mumbai Ltd (AEML) Gorai substation. The study model developed in the PSCAD. It includes a model for VSR, Sf6 CB, other substation equipments. Inrush currents due to uncontrolled switching and transient recovery voltage peak due to forced 5A current chopping corresponding to lowest 48 MVAr (40%) and highest 120 MVAr (100%) reactive power were determined. Based on the analysis, controlled switching device (CSD) was proposed for point on wave switching strategy for 120 MVAr VSR and operational methodology is devised.","PeriodicalId":284783,"journal":{"name":"2022 International Conference on Computational Intelligence and Sustainable Engineering Solutions (CISES)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transient Switching Study for 120 MVAr Variable Shunt Reactor at 220 kV Substation\",\"authors\":\"Ayyaj S Maner, Amol Salunkhe, Raiju Hassan, Sonu Karekar, Mahesh Ambardekar, Arvindkumar Sharma\",\"doi\":\"10.1109/CISES54857.2022.9844359\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes transients switching study carried out for variable shunt reactor (VSR) connected to 220 kV Grid at 220/33 kV Adani Electricity Mumbai Ltd (AEML) Gorai substation. The study model developed in the PSCAD. It includes a model for VSR, Sf6 CB, other substation equipments. Inrush currents due to uncontrolled switching and transient recovery voltage peak due to forced 5A current chopping corresponding to lowest 48 MVAr (40%) and highest 120 MVAr (100%) reactive power were determined. Based on the analysis, controlled switching device (CSD) was proposed for point on wave switching strategy for 120 MVAr VSR and operational methodology is devised.\",\"PeriodicalId\":284783,\"journal\":{\"name\":\"2022 International Conference on Computational Intelligence and Sustainable Engineering Solutions (CISES)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Computational Intelligence and Sustainable Engineering Solutions (CISES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CISES54857.2022.9844359\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Computational Intelligence and Sustainable Engineering Solutions (CISES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CISES54857.2022.9844359","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文描述了在220/33千伏阿达尼电力孟买有限公司(AEML)戈莱变电站连接220千伏电网的可变并联电抗器(VSR)的瞬态开关研究。该研究模型是在PSCAD中开发的。它包括VSR, Sf6 CB和其他变电站设备的模型。确定了无功功率最低48 MVAr(40%)和最高120 MVAr(100%)时,不受控制开关引起的涌流和强制5A电流斩波引起的暂态恢复电压峰值。在此基础上,提出了采用可控开关装置(CSD)实现120 MVAr VSR的点波开关策略,并设计了操作方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transient Switching Study for 120 MVAr Variable Shunt Reactor at 220 kV Substation
This paper describes transients switching study carried out for variable shunt reactor (VSR) connected to 220 kV Grid at 220/33 kV Adani Electricity Mumbai Ltd (AEML) Gorai substation. The study model developed in the PSCAD. It includes a model for VSR, Sf6 CB, other substation equipments. Inrush currents due to uncontrolled switching and transient recovery voltage peak due to forced 5A current chopping corresponding to lowest 48 MVAr (40%) and highest 120 MVAr (100%) reactive power were determined. Based on the analysis, controlled switching device (CSD) was proposed for point on wave switching strategy for 120 MVAr VSR and operational methodology is devised.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信