加拿大住宅漏风影响因素调查

M. Ismaiel, Yuxiang Chen
{"title":"加拿大住宅漏风影响因素调查","authors":"M. Ismaiel, Yuxiang Chen","doi":"10.29173/MOCS136","DOIUrl":null,"url":null,"abstract":"Air leakage is one of the main influencing factors in buildings’ thermal performance. The adverse effects of poor air leakage include higher energy costs, consumption in space heating and cooling, poor thermal comfort, corrosion, and the growth of molds due to air leakage induced condensation. The main objective of this study is to investigate the characteristics of air leakages of Canadian homes related to construction methods, age, size and climatic zones. The air leakage test results of 226,000 dwellings in three provinces of Canada were analyzed. Statistical analysis was utilized to compare the mean of air leakage with respect to different factors. Generally, the air leakage decreased by 40% in the period from 1960 until 2018, which has shown a remarkable effect of new construction techniques on air leakage. Investigations also indicated that the average air leakage rate of homes constructed by using the onsite technique is approximately 25% to 60% higher than those prefabricated in modular or panels, varying with respect to the workmanship and construction quality control. This study concluded that the prefabricated construction techniques could decrease the air leakage rate significantly, which will have a remarkable effect on buildings’ thermal performance as well as home’s heating and cooling costs. The findings contribute to estimating the effects of influencing factors on air leakage, also it is useful in performance simulations, HAVC sizing and energy management. And recommend the use of the prefabricated in modular or panel’s construction method to achieve better and acceptable air leakage performance.","PeriodicalId":422911,"journal":{"name":"Modular and Offsite Construction (MOC) Summit Proceedings","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Investigation of Influencing Factors on Air Leakage of Canadian Dwellings\",\"authors\":\"M. Ismaiel, Yuxiang Chen\",\"doi\":\"10.29173/MOCS136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Air leakage is one of the main influencing factors in buildings’ thermal performance. The adverse effects of poor air leakage include higher energy costs, consumption in space heating and cooling, poor thermal comfort, corrosion, and the growth of molds due to air leakage induced condensation. The main objective of this study is to investigate the characteristics of air leakages of Canadian homes related to construction methods, age, size and climatic zones. The air leakage test results of 226,000 dwellings in three provinces of Canada were analyzed. Statistical analysis was utilized to compare the mean of air leakage with respect to different factors. Generally, the air leakage decreased by 40% in the period from 1960 until 2018, which has shown a remarkable effect of new construction techniques on air leakage. Investigations also indicated that the average air leakage rate of homes constructed by using the onsite technique is approximately 25% to 60% higher than those prefabricated in modular or panels, varying with respect to the workmanship and construction quality control. This study concluded that the prefabricated construction techniques could decrease the air leakage rate significantly, which will have a remarkable effect on buildings’ thermal performance as well as home’s heating and cooling costs. The findings contribute to estimating the effects of influencing factors on air leakage, also it is useful in performance simulations, HAVC sizing and energy management. And recommend the use of the prefabricated in modular or panel’s construction method to achieve better and acceptable air leakage performance.\",\"PeriodicalId\":422911,\"journal\":{\"name\":\"Modular and Offsite Construction (MOC) Summit Proceedings\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Modular and Offsite Construction (MOC) Summit Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29173/MOCS136\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Modular and Offsite Construction (MOC) Summit Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29173/MOCS136","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

漏风是影响建筑热工性能的主要因素之一。漏风不良的不良影响包括较高的能源成本,空间供暖和制冷消耗,热舒适性差,腐蚀以及由于漏风引起的冷凝导致模具生长。本研究的主要目的是调查加拿大房屋与建筑方法、年龄、大小和气候带有关的空气泄漏特征。分析了加拿大三个省226,000个住宅的漏风测试结果。采用统计分析的方法比较了不同因素下的漏风平均值。总体而言,从1960年到2018年,漏风量下降了40%,这表明新施工技术对漏风的影响显著。调查还表明,采用现场技术建造的房屋的平均漏风率比采用模块化或面板预制的房屋高出约25%至60%,这与工艺和施工质量控制有关。研究结果表明,装配式建筑技术可以显著降低漏风率,这将对建筑的热工性能和家庭的供暖和制冷成本产生显著影响。研究结果有助于估计影响因素对空气泄漏的影响,并在性能模拟,HAVC尺寸和能量管理方面具有重要意义。并建议使用预制的模块化或面板的施工方法,以达到更好的和可接受的漏风性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of Influencing Factors on Air Leakage of Canadian Dwellings
Air leakage is one of the main influencing factors in buildings’ thermal performance. The adverse effects of poor air leakage include higher energy costs, consumption in space heating and cooling, poor thermal comfort, corrosion, and the growth of molds due to air leakage induced condensation. The main objective of this study is to investigate the characteristics of air leakages of Canadian homes related to construction methods, age, size and climatic zones. The air leakage test results of 226,000 dwellings in three provinces of Canada were analyzed. Statistical analysis was utilized to compare the mean of air leakage with respect to different factors. Generally, the air leakage decreased by 40% in the period from 1960 until 2018, which has shown a remarkable effect of new construction techniques on air leakage. Investigations also indicated that the average air leakage rate of homes constructed by using the onsite technique is approximately 25% to 60% higher than those prefabricated in modular or panels, varying with respect to the workmanship and construction quality control. This study concluded that the prefabricated construction techniques could decrease the air leakage rate significantly, which will have a remarkable effect on buildings’ thermal performance as well as home’s heating and cooling costs. The findings contribute to estimating the effects of influencing factors on air leakage, also it is useful in performance simulations, HAVC sizing and energy management. And recommend the use of the prefabricated in modular or panel’s construction method to achieve better and acceptable air leakage performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信