{"title":"基于CO/ sub2 /-和量子级联激光器作为泵浦源的多组分痕量气体监测移动激光光声光谱仪","authors":"M. Nagele, D. Hofstetter, J. Faist, M. Sigrist","doi":"10.1109/CLEOE.2000.909779","DOIUrl":null,"url":null,"abstract":"Summary form only given. The development and application of a mobile laser-photoacoustic spectrometer for in-situ multicomponent monitoring of trace gases in different environments is reported. Sub-ppbV (<10/sup -9/ per volume)-concentrations can be measured with a novel resonant multipass photoacoustic cell. For ethene (C/sub 2/H/sub 4/) buffered in synthetic air a minimum detection limit of 70 pptV (70/spl times/10/sup -12/ per volume) is achieved with a line-tunable CO/sub 2/-laser as pump source corresponding to a minimum measurable absorption coefficient /spl alpha//sub min/=2/spl times/10/sup -9/ cm/sup -1/ for a signal-to-noise ratio of 3. The multicomponent capability of the system is demonstrated with continuous sequential measurements of gases such as ethene, methanol, and ethanol of air from a fruit storage chamber.","PeriodicalId":250878,"journal":{"name":"Conference Digest. 2000 Conference on Lasers and Electro-Optics Europe (Cat. No.00TH8505)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Mobile laser photoacoustic spectrometer for multicomponent trace-gas monitoring based on CO/sub 2/- and quantum-cascade lasers as pump sources\",\"authors\":\"M. Nagele, D. Hofstetter, J. Faist, M. Sigrist\",\"doi\":\"10.1109/CLEOE.2000.909779\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Summary form only given. The development and application of a mobile laser-photoacoustic spectrometer for in-situ multicomponent monitoring of trace gases in different environments is reported. Sub-ppbV (<10/sup -9/ per volume)-concentrations can be measured with a novel resonant multipass photoacoustic cell. For ethene (C/sub 2/H/sub 4/) buffered in synthetic air a minimum detection limit of 70 pptV (70/spl times/10/sup -12/ per volume) is achieved with a line-tunable CO/sub 2/-laser as pump source corresponding to a minimum measurable absorption coefficient /spl alpha//sub min/=2/spl times/10/sup -9/ cm/sup -1/ for a signal-to-noise ratio of 3. The multicomponent capability of the system is demonstrated with continuous sequential measurements of gases such as ethene, methanol, and ethanol of air from a fruit storage chamber.\",\"PeriodicalId\":250878,\"journal\":{\"name\":\"Conference Digest. 2000 Conference on Lasers and Electro-Optics Europe (Cat. No.00TH8505)\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Digest. 2000 Conference on Lasers and Electro-Optics Europe (Cat. No.00TH8505)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CLEOE.2000.909779\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Digest. 2000 Conference on Lasers and Electro-Optics Europe (Cat. No.00TH8505)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CLEOE.2000.909779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Mobile laser photoacoustic spectrometer for multicomponent trace-gas monitoring based on CO/sub 2/- and quantum-cascade lasers as pump sources
Summary form only given. The development and application of a mobile laser-photoacoustic spectrometer for in-situ multicomponent monitoring of trace gases in different environments is reported. Sub-ppbV (<10/sup -9/ per volume)-concentrations can be measured with a novel resonant multipass photoacoustic cell. For ethene (C/sub 2/H/sub 4/) buffered in synthetic air a minimum detection limit of 70 pptV (70/spl times/10/sup -12/ per volume) is achieved with a line-tunable CO/sub 2/-laser as pump source corresponding to a minimum measurable absorption coefficient /spl alpha//sub min/=2/spl times/10/sup -9/ cm/sup -1/ for a signal-to-noise ratio of 3. The multicomponent capability of the system is demonstrated with continuous sequential measurements of gases such as ethene, methanol, and ethanol of air from a fruit storage chamber.