V. Melikyan, A. Sahakyan, Mikayel Piloyan, G. Hovhannisyan, Aram Shishmanyan, T. Hovhannisyan, Davit Trdatyan
{"title":"无外部精密元件的电阻校准方法","authors":"V. Melikyan, A. Sahakyan, Mikayel Piloyan, G. Hovhannisyan, Aram Shishmanyan, T. Hovhannisyan, Davit Trdatyan","doi":"10.1109/EWDTS.2014.7027071","DOIUrl":null,"url":null,"abstract":"A method of resistance calibration without external precision elements usage presented in paper. In the proposed method, used structures which operation based on technologically accurate elements and signals to have high accuracy resistance after calibration. Architecture produces a calibration code corresponding to 50Ohms PVT compensated termination impedance, which is needed to avoid reflections in transmission lines. Standard calibration methods using external ~1% accuracy precision discreet resistance (50 or 200Ohms). The presented calibration mechanism using internal elements and can provide ~ 4-7% accuracy of calibration. Method can be used in the special input/output circuits of several standards such as Peripheral Component Interconnect (PCI), Universal Serial Bus (USB), Double Data Rate (DDR) etc.","PeriodicalId":272780,"journal":{"name":"Proceedings of IEEE East-West Design & Test Symposium (EWDTS 2014)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Resistance calibration method without external precision elements\",\"authors\":\"V. Melikyan, A. Sahakyan, Mikayel Piloyan, G. Hovhannisyan, Aram Shishmanyan, T. Hovhannisyan, Davit Trdatyan\",\"doi\":\"10.1109/EWDTS.2014.7027071\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method of resistance calibration without external precision elements usage presented in paper. In the proposed method, used structures which operation based on technologically accurate elements and signals to have high accuracy resistance after calibration. Architecture produces a calibration code corresponding to 50Ohms PVT compensated termination impedance, which is needed to avoid reflections in transmission lines. Standard calibration methods using external ~1% accuracy precision discreet resistance (50 or 200Ohms). The presented calibration mechanism using internal elements and can provide ~ 4-7% accuracy of calibration. Method can be used in the special input/output circuits of several standards such as Peripheral Component Interconnect (PCI), Universal Serial Bus (USB), Double Data Rate (DDR) etc.\",\"PeriodicalId\":272780,\"journal\":{\"name\":\"Proceedings of IEEE East-West Design & Test Symposium (EWDTS 2014)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IEEE East-West Design & Test Symposium (EWDTS 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EWDTS.2014.7027071\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE East-West Design & Test Symposium (EWDTS 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EWDTS.2014.7027071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
本文提出了一种无需外部精密元件的电阻校准方法。在该方法中,采用基于技术精确元件和信号运行的结构,校正后具有较高的精度电阻。架构产生对应于50欧姆PVT补偿终端阻抗的校准代码,该代码需要避免传输线中的反射。标准校准方法采用外部~1%精度的离散电阻(50或200欧姆)。所提出的校准机构采用内部元件,可提供~ 4-7%的校准精度。该方法可用于PCI (Peripheral Component Interconnect)、USB (Universal Serial Bus)、DDR (Double Data Rate)等标准的特殊输入/输出电路。
Resistance calibration method without external precision elements
A method of resistance calibration without external precision elements usage presented in paper. In the proposed method, used structures which operation based on technologically accurate elements and signals to have high accuracy resistance after calibration. Architecture produces a calibration code corresponding to 50Ohms PVT compensated termination impedance, which is needed to avoid reflections in transmission lines. Standard calibration methods using external ~1% accuracy precision discreet resistance (50 or 200Ohms). The presented calibration mechanism using internal elements and can provide ~ 4-7% accuracy of calibration. Method can be used in the special input/output circuits of several standards such as Peripheral Component Interconnect (PCI), Universal Serial Bus (USB), Double Data Rate (DDR) etc.