{"title":"德黑兰配电公司电能质量指标评价","authors":"H. Siahkali","doi":"10.1109/PCT.2007.4538608","DOIUrl":null,"url":null,"abstract":"Power quality has become an increasing concern to utilities and customers. The increased concern has resulted in measuring power quality variations and characteristic disturbances for different distribution companies. This paper explains the results of power quality indexes for 50 customer loads at two voltage levels 20kV and 400v. The measurement period is 7 days with 10 minutes intervals. Also this survey has been presented according to IEC61000 and Iranian Power Quality Standard (IPQS). IPQS has some differences from IEC61000, EN50160 and IEEE standards in power quality indexes, which are investigated in this paper. At the end of paper, individual and global power indicators for all disturbances and a set of measurement instruments are introduced and applied to these data collections, respectively. These indicators have been defined to easily understand and implement by operators.","PeriodicalId":356805,"journal":{"name":"2007 IEEE Lausanne Power Tech","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Assessment of Power Quality Indexes In Tehran Distribution Company\",\"authors\":\"H. Siahkali\",\"doi\":\"10.1109/PCT.2007.4538608\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power quality has become an increasing concern to utilities and customers. The increased concern has resulted in measuring power quality variations and characteristic disturbances for different distribution companies. This paper explains the results of power quality indexes for 50 customer loads at two voltage levels 20kV and 400v. The measurement period is 7 days with 10 minutes intervals. Also this survey has been presented according to IEC61000 and Iranian Power Quality Standard (IPQS). IPQS has some differences from IEC61000, EN50160 and IEEE standards in power quality indexes, which are investigated in this paper. At the end of paper, individual and global power indicators for all disturbances and a set of measurement instruments are introduced and applied to these data collections, respectively. These indicators have been defined to easily understand and implement by operators.\",\"PeriodicalId\":356805,\"journal\":{\"name\":\"2007 IEEE Lausanne Power Tech\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Lausanne Power Tech\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCT.2007.4538608\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Lausanne Power Tech","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCT.2007.4538608","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

电力质量已成为公用事业和客户日益关注的问题。这种日益增加的关注导致了对不同配电公司的电能质量变化和特性干扰的测量。本文介绍了50个客户负荷在20kV和400v两个电压等级下的电能质量指标的计算结果。测量周期为7天,每隔10分钟测量一次。此外,该调查已根据IEC61000和伊朗电力质量标准(IPQS)提出。IPQS在电能质量指标方面与IEC61000、EN50160和IEEE标准存在一定的差异,本文对这些差异进行了分析。在论文的最后,介绍了所有干扰的单个和全局功率指标以及一套测量仪器,并分别应用于这些数据收集。这些指标已经定义,便于操作人员理解和实施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of Power Quality Indexes In Tehran Distribution Company
Power quality has become an increasing concern to utilities and customers. The increased concern has resulted in measuring power quality variations and characteristic disturbances for different distribution companies. This paper explains the results of power quality indexes for 50 customer loads at two voltage levels 20kV and 400v. The measurement period is 7 days with 10 minutes intervals. Also this survey has been presented according to IEC61000 and Iranian Power Quality Standard (IPQS). IPQS has some differences from IEC61000, EN50160 and IEEE standards in power quality indexes, which are investigated in this paper. At the end of paper, individual and global power indicators for all disturbances and a set of measurement instruments are introduced and applied to these data collections, respectively. These indicators have been defined to easily understand and implement by operators.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信