{"title":"交流可编程约瑟夫森电压标准取样测量系统的不确定度评定","authors":"Shih-Fang Chen, Y. Amagai, M. Maruyama, N. Kaneko","doi":"10.1109/CPEM.2014.6898357","DOIUrl":null,"url":null,"abstract":"We have evaluated the uncertainty in the differential sampling measurement of 10 Vrms waveform synthesis based on an AC-programmable Josephson voltage standard (AC-PJVS) with a modified digital voltmeter (DVM). The error due to sampling timer is much reduced with an external 20 MHz frequency reference for the DVM. The type B uncertainty level of smaller than 1 μV/V is expected for the differential sampling measurement of a 10 Vrms sine wave generated by a calibrator.","PeriodicalId":256575,"journal":{"name":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","volume":"01 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Uncertainty evaluation of sampling measurement system using AC-programmable Josephson voltage standard\",\"authors\":\"Shih-Fang Chen, Y. Amagai, M. Maruyama, N. Kaneko\",\"doi\":\"10.1109/CPEM.2014.6898357\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have evaluated the uncertainty in the differential sampling measurement of 10 Vrms waveform synthesis based on an AC-programmable Josephson voltage standard (AC-PJVS) with a modified digital voltmeter (DVM). The error due to sampling timer is much reduced with an external 20 MHz frequency reference for the DVM. The type B uncertainty level of smaller than 1 μV/V is expected for the differential sampling measurement of a 10 Vrms sine wave generated by a calibrator.\",\"PeriodicalId\":256575,\"journal\":{\"name\":\"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)\",\"volume\":\"01 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2014.6898357\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2014.6898357","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Uncertainty evaluation of sampling measurement system using AC-programmable Josephson voltage standard
We have evaluated the uncertainty in the differential sampling measurement of 10 Vrms waveform synthesis based on an AC-programmable Josephson voltage standard (AC-PJVS) with a modified digital voltmeter (DVM). The error due to sampling timer is much reduced with an external 20 MHz frequency reference for the DVM. The type B uncertainty level of smaller than 1 μV/V is expected for the differential sampling measurement of a 10 Vrms sine wave generated by a calibrator.