采用铝导体的50KVA 10 / 0.23KV配电变压器设计创新利马南部电气化项目

Margarita Murillo Manrique, Gerson Robledo Benítez
{"title":"采用铝导体的50KVA 10 / 0.23KV配电变压器设计创新利马南部电气化项目","authors":"Margarita Murillo Manrique, Gerson Robledo Benítez","doi":"10.1109/SHIRCON53068.2021.9652289","DOIUrl":null,"url":null,"abstract":"The research describes the design of a transformer based on aluminum electrical conductors whose properties of conductivity, resistivity, weight and section present us with an innovative alternative for the massive electrification projects developed by the electric power concessionaires. For the design, the theoretical calculations are considered, the dimensioning of the aluminum conductor based on the efficiency of the traditional transformer that uses copper conductors for the electrical substations in the southern area of Lima. For the development of this model, the protocols of seven transformers were used, whose historical data were analyzed and considered to determine the viability, reliability and efficiency of the new 50KVA 10 / 0.23kV transformer ± 5% Dyn5 connection based on aluminum conductors. The results obtained were highly significant considering that the proposed model responds to the protocols of the sample transformers.","PeriodicalId":420900,"journal":{"name":"2021 IEEE Sciences and Humanities International Research Conference (SHIRCON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of 50KVA 10 / 0.23KV Distribution Transformers using Aluminum Electrical Conductors to innovate Electrification Projects in the South of Lima\",\"authors\":\"Margarita Murillo Manrique, Gerson Robledo Benítez\",\"doi\":\"10.1109/SHIRCON53068.2021.9652289\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The research describes the design of a transformer based on aluminum electrical conductors whose properties of conductivity, resistivity, weight and section present us with an innovative alternative for the massive electrification projects developed by the electric power concessionaires. For the design, the theoretical calculations are considered, the dimensioning of the aluminum conductor based on the efficiency of the traditional transformer that uses copper conductors for the electrical substations in the southern area of Lima. For the development of this model, the protocols of seven transformers were used, whose historical data were analyzed and considered to determine the viability, reliability and efficiency of the new 50KVA 10 / 0.23kV transformer ± 5% Dyn5 connection based on aluminum conductors. The results obtained were highly significant considering that the proposed model responds to the protocols of the sample transformers.\",\"PeriodicalId\":420900,\"journal\":{\"name\":\"2021 IEEE Sciences and Humanities International Research Conference (SHIRCON)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE Sciences and Humanities International Research Conference (SHIRCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SHIRCON53068.2021.9652289\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Sciences and Humanities International Research Conference (SHIRCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SHIRCON53068.2021.9652289","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

该研究描述了一种基于铝导体的变压器的设计,其导电性、电阻率、重量和截面的特性为电力特许经营公司开发的大规模电气化项目提供了一种创新的替代方案。在设计中,根据利马南部地区变电站使用铜导体的传统变压器的效率,考虑了铝导体尺寸的理论计算。为建立该模型,采用了7台变压器的协议,对其历史数据进行了分析和考虑,以确定基于铝导体的新型50KVA 10 / 0.23kV±5% Dyn5接线的可行性、可靠性和效率。考虑到所提出的模型响应样品变压器的协议,所获得的结果是非常重要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of 50KVA 10 / 0.23KV Distribution Transformers using Aluminum Electrical Conductors to innovate Electrification Projects in the South of Lima
The research describes the design of a transformer based on aluminum electrical conductors whose properties of conductivity, resistivity, weight and section present us with an innovative alternative for the massive electrification projects developed by the electric power concessionaires. For the design, the theoretical calculations are considered, the dimensioning of the aluminum conductor based on the efficiency of the traditional transformer that uses copper conductors for the electrical substations in the southern area of Lima. For the development of this model, the protocols of seven transformers were used, whose historical data were analyzed and considered to determine the viability, reliability and efficiency of the new 50KVA 10 / 0.23kV transformer ± 5% Dyn5 connection based on aluminum conductors. The results obtained were highly significant considering that the proposed model responds to the protocols of the sample transformers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信