一种利用液体延迟线振荡器的机械振动传感技术

T. Fujita, K. Toda
{"title":"一种利用液体延迟线振荡器的机械振动传感技术","authors":"T. Fujita, K. Toda","doi":"10.1109/ULTSYM.2002.1193541","DOIUrl":null,"url":null,"abstract":"A technique for measuring mechanical vibration displacement is proposed using a liquid-delay-line-oscillator, which is composed of two pairs of arch-shaped interdigital transducers (IDTs) on a double-layered substrate composed of a piezoelectric ceramic plate and an acrylic plate, a polymer-film diaphragm as one wall of a liquid cavity, and a water layer. The diaphragm functions as an ultrasound-beam reflector. The acoustical phase change arises corresponding to the pressure exerted on the central part of the diaphragm. The relationship between the mechanical displacement and the oscillation frequency is evaluated experimentally on the basis of the acoustical delay length linearly dependent on the thickness of the water layer. The static and dynamic displacement measurements are demonstrated. The present technique is promising for sensing sound pressure, which could be regarded as a precise and convenient method.","PeriodicalId":378705,"journal":{"name":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A mechanical vibration sensing technique using a liquid delay line oscillator\",\"authors\":\"T. Fujita, K. Toda\",\"doi\":\"10.1109/ULTSYM.2002.1193541\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A technique for measuring mechanical vibration displacement is proposed using a liquid-delay-line-oscillator, which is composed of two pairs of arch-shaped interdigital transducers (IDTs) on a double-layered substrate composed of a piezoelectric ceramic plate and an acrylic plate, a polymer-film diaphragm as one wall of a liquid cavity, and a water layer. The diaphragm functions as an ultrasound-beam reflector. The acoustical phase change arises corresponding to the pressure exerted on the central part of the diaphragm. The relationship between the mechanical displacement and the oscillation frequency is evaluated experimentally on the basis of the acoustical delay length linearly dependent on the thickness of the water layer. The static and dynamic displacement measurements are demonstrated. The present technique is promising for sensing sound pressure, which could be regarded as a precise and convenient method.\",\"PeriodicalId\":378705,\"journal\":{\"name\":\"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2002.1193541\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2002.1193541","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种测量机械振动位移的技术,该技术由两对拱形数字间换能器(IDTs)组成,该换能器安装在由压电陶瓷板和丙烯酸板、聚合物薄膜隔膜作为液腔壁和水层组成的双层衬底上。隔膜的作用是作为超声波光束反射器。声相位的变化与施加在隔膜中央部分的压力相对应。在声学延迟长度与水层厚度线性相关的基础上,实验评估了机械位移与振荡频率之间的关系。演示了静态和动态位移测量。该方法是一种精确、方便的声压检测方法,具有广阔的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A mechanical vibration sensing technique using a liquid delay line oscillator
A technique for measuring mechanical vibration displacement is proposed using a liquid-delay-line-oscillator, which is composed of two pairs of arch-shaped interdigital transducers (IDTs) on a double-layered substrate composed of a piezoelectric ceramic plate and an acrylic plate, a polymer-film diaphragm as one wall of a liquid cavity, and a water layer. The diaphragm functions as an ultrasound-beam reflector. The acoustical phase change arises corresponding to the pressure exerted on the central part of the diaphragm. The relationship between the mechanical displacement and the oscillation frequency is evaluated experimentally on the basis of the acoustical delay length linearly dependent on the thickness of the water layer. The static and dynamic displacement measurements are demonstrated. The present technique is promising for sensing sound pressure, which could be regarded as a precise and convenient method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信