{"title":"太阳能系统DC-DC升压变换器的鲁棒控制","authors":"Yeqin Wang, B. Ren, Qing-Chang Zhong","doi":"10.23919/ACC.2017.7963741","DOIUrl":null,"url":null,"abstract":"It is very challenging to control a DC-DC boost converter, due to its non-minimum phase phenomenon, model uncertainties (e.g., the parasitics), and external disturbances (e.g., input voltage change or load change). In this paper, a uncertainty and disturbance estimator (UDE)-based current-mode control (CMC) is proposed to address these problems. A new voltage dynamics is developed to avoid the non-minimum phase phenomenon. Then the UDE algorithm is adopted for both voltage-loop control design and current-loop control design to deal with model uncertainties, external disturbances, and the inductor current estimation error. Furthermore, a new control framework based on this UDE-based CMC is proposed for the grid integration of solar systems with voltage protection. Experimental results are provided to demonstrate the effectiveness and robustness of the proposed strategies.","PeriodicalId":422926,"journal":{"name":"2017 American Control Conference (ACC)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Robust control of DC-DC boost converters for solar systems\",\"authors\":\"Yeqin Wang, B. Ren, Qing-Chang Zhong\",\"doi\":\"10.23919/ACC.2017.7963741\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is very challenging to control a DC-DC boost converter, due to its non-minimum phase phenomenon, model uncertainties (e.g., the parasitics), and external disturbances (e.g., input voltage change or load change). In this paper, a uncertainty and disturbance estimator (UDE)-based current-mode control (CMC) is proposed to address these problems. A new voltage dynamics is developed to avoid the non-minimum phase phenomenon. Then the UDE algorithm is adopted for both voltage-loop control design and current-loop control design to deal with model uncertainties, external disturbances, and the inductor current estimation error. Furthermore, a new control framework based on this UDE-based CMC is proposed for the grid integration of solar systems with voltage protection. Experimental results are provided to demonstrate the effectiveness and robustness of the proposed strategies.\",\"PeriodicalId\":422926,\"journal\":{\"name\":\"2017 American Control Conference (ACC)\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 American Control Conference (ACC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/ACC.2017.7963741\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 American Control Conference (ACC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ACC.2017.7963741","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Robust control of DC-DC boost converters for solar systems
It is very challenging to control a DC-DC boost converter, due to its non-minimum phase phenomenon, model uncertainties (e.g., the parasitics), and external disturbances (e.g., input voltage change or load change). In this paper, a uncertainty and disturbance estimator (UDE)-based current-mode control (CMC) is proposed to address these problems. A new voltage dynamics is developed to avoid the non-minimum phase phenomenon. Then the UDE algorithm is adopted for both voltage-loop control design and current-loop control design to deal with model uncertainties, external disturbances, and the inductor current estimation error. Furthermore, a new control framework based on this UDE-based CMC is proposed for the grid integration of solar systems with voltage protection. Experimental results are provided to demonstrate the effectiveness and robustness of the proposed strategies.