{"title":"热视觉和光谱辐射测量法在化学污染检测中的应用","authors":"Marek Chmiel, M. Kastek, D. Całus, K. Szczepański","doi":"10.1515/oszn-2017-0019","DOIUrl":null,"url":null,"abstract":"Abstract The range of applications in which remote detection of chemical compounds is used extends from monitoring of technological processes through diagnostics of industrial installation and environmental control up to military applications. The methods and the devices used for the passive detection of selected gases are presented. The change in the signal reaching the camera caused by the presence of gas was calculated. The successful detection can be achieved if the absorption (or emission) of a gas cloud, located between object (background) and the camera, causes signal change greater or equal to noise equivalent temperature difference (NETD) of the camera.","PeriodicalId":369211,"journal":{"name":"Ochrona Srodowiska i Zasobów Naturalnych","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermovision and spectroradiometry in stand-off detection of chemical contamination\",\"authors\":\"Marek Chmiel, M. Kastek, D. Całus, K. Szczepański\",\"doi\":\"10.1515/oszn-2017-0019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The range of applications in which remote detection of chemical compounds is used extends from monitoring of technological processes through diagnostics of industrial installation and environmental control up to military applications. The methods and the devices used for the passive detection of selected gases are presented. The change in the signal reaching the camera caused by the presence of gas was calculated. The successful detection can be achieved if the absorption (or emission) of a gas cloud, located between object (background) and the camera, causes signal change greater or equal to noise equivalent temperature difference (NETD) of the camera.\",\"PeriodicalId\":369211,\"journal\":{\"name\":\"Ochrona Srodowiska i Zasobów Naturalnych\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ochrona Srodowiska i Zasobów Naturalnych\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/oszn-2017-0019\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ochrona Srodowiska i Zasobów Naturalnych","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/oszn-2017-0019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Thermovision and spectroradiometry in stand-off detection of chemical contamination
Abstract The range of applications in which remote detection of chemical compounds is used extends from monitoring of technological processes through diagnostics of industrial installation and environmental control up to military applications. The methods and the devices used for the passive detection of selected gases are presented. The change in the signal reaching the camera caused by the presence of gas was calculated. The successful detection can be achieved if the absorption (or emission) of a gas cloud, located between object (background) and the camera, causes signal change greater or equal to noise equivalent temperature difference (NETD) of the camera.