{"title":"一种利用相关和互相关系数检测单相电路有功和无功电流的新方法及其应用","authors":"T. Tanaka, K. Ueda, K. Satou, S. Fukuma","doi":"10.1109/IAS.2004.1348510","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel method of detecting the active and reactive currents in single-phase circuits using the correlation and cross-correlation coefficients in the time domain. The active current is detected using the correlation coefficient between the source voltage and load current waveforms, and the reactive current is detected using the cross-correlation coefficient. The basic principle of the proposed detection method is discussed, and the proposed method is applied to a previously proposed single-phase shunt active filter for consumer electronic equipment. Simulation and experimental results demonstrate the excellent practicability of the proposed detection method.","PeriodicalId":131410,"journal":{"name":"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A novel detection method of active and reactive currents in single-phase circuits using the correlation and cross-correlation coefficients and its applications\",\"authors\":\"T. Tanaka, K. Ueda, K. Satou, S. Fukuma\",\"doi\":\"10.1109/IAS.2004.1348510\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a novel method of detecting the active and reactive currents in single-phase circuits using the correlation and cross-correlation coefficients in the time domain. The active current is detected using the correlation coefficient between the source voltage and load current waveforms, and the reactive current is detected using the cross-correlation coefficient. The basic principle of the proposed detection method is discussed, and the proposed method is applied to a previously proposed single-phase shunt active filter for consumer electronic equipment. Simulation and experimental results demonstrate the excellent practicability of the proposed detection method.\",\"PeriodicalId\":131410,\"journal\":{\"name\":\"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2004.1348510\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2004.1348510","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A novel detection method of active and reactive currents in single-phase circuits using the correlation and cross-correlation coefficients and its applications
This paper proposes a novel method of detecting the active and reactive currents in single-phase circuits using the correlation and cross-correlation coefficients in the time domain. The active current is detected using the correlation coefficient between the source voltage and load current waveforms, and the reactive current is detected using the cross-correlation coefficient. The basic principle of the proposed detection method is discussed, and the proposed method is applied to a previously proposed single-phase shunt active filter for consumer electronic equipment. Simulation and experimental results demonstrate the excellent practicability of the proposed detection method.