G. Domański, R. Szabatin, J. Kalenik, Adam Jaworski, P. Wróblewski, W. Smolik, R. Kurjata, B. Konarzewski, M. Dziewiecki, J. Marzec, K. Zaremba, M. Ziembicki, A. Rychter, J. Kryszyn, P. Brzeski, J. Szmidt
{"title":"单箔型气体电子倍增探测器的增益预测理论","authors":"G. Domański, R. Szabatin, J. Kalenik, Adam Jaworski, P. Wróblewski, W. Smolik, R. Kurjata, B. Konarzewski, M. Dziewiecki, J. Marzec, K. Zaremba, M. Ziembicki, A. Rychter, J. Kryszyn, P. Brzeski, J. Szmidt","doi":"10.5604/01.3001.0010.4601","DOIUrl":null,"url":null,"abstract":"Gain prediction theory of single foil Gas Electron Multiplier detector was developed. Gas electron multiplier (GEM) detector with single foil was developed. Soft X-ray spectra with an energy of 5.9 keV emitted by the isotope Fe-55 were measured. On this basis, the dependence of gain and energy resolution from the detector voltage was determined. The simple theory of gain dependence on various detector parameters was developed. Preliminary results of the study confirmed the potential usefulness of the GEM detector as a substitute for the multiwire proportional chamber.","PeriodicalId":142227,"journal":{"name":"Informatics, Control, Measurement in Economy and Environment Protection","volume":"14 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Gain prediction theory of single foil gas electron multiplier detector\",\"authors\":\"G. Domański, R. Szabatin, J. Kalenik, Adam Jaworski, P. Wróblewski, W. Smolik, R. Kurjata, B. Konarzewski, M. Dziewiecki, J. Marzec, K. Zaremba, M. Ziembicki, A. Rychter, J. Kryszyn, P. Brzeski, J. Szmidt\",\"doi\":\"10.5604/01.3001.0010.4601\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Gain prediction theory of single foil Gas Electron Multiplier detector was developed. Gas electron multiplier (GEM) detector with single foil was developed. Soft X-ray spectra with an energy of 5.9 keV emitted by the isotope Fe-55 were measured. On this basis, the dependence of gain and energy resolution from the detector voltage was determined. The simple theory of gain dependence on various detector parameters was developed. Preliminary results of the study confirmed the potential usefulness of the GEM detector as a substitute for the multiwire proportional chamber.\",\"PeriodicalId\":142227,\"journal\":{\"name\":\"Informatics, Control, Measurement in Economy and Environment Protection\",\"volume\":\"14 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-03-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Informatics, Control, Measurement in Economy and Environment Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5604/01.3001.0010.4601\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Informatics, Control, Measurement in Economy and Environment Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0010.4601","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Gain prediction theory of single foil gas electron multiplier detector
Gain prediction theory of single foil Gas Electron Multiplier detector was developed. Gas electron multiplier (GEM) detector with single foil was developed. Soft X-ray spectra with an energy of 5.9 keV emitted by the isotope Fe-55 were measured. On this basis, the dependence of gain and energy resolution from the detector voltage was determined. The simple theory of gain dependence on various detector parameters was developed. Preliminary results of the study confirmed the potential usefulness of the GEM detector as a substitute for the multiwire proportional chamber.