鸭子曲线与可再生能源和存储技术

Giovani Manuel Pitra, Musti K. S. Sastry
{"title":"鸭子曲线与可再生能源和存储技术","authors":"Giovani Manuel Pitra, Musti K. S. Sastry","doi":"10.1109/CICN51697.2021.9574671","DOIUrl":null,"url":null,"abstract":"Duck curve phenomena occurs when solar energy in higher quantities is integrated into the power grid. This results in excess generation that cannot be delivered during peak hours and a part of the load that cannot be supplied during off-peak hours. This paper proposes a novel, 2-step methodology to determine the effects of duck curve and also to flatten the same. This methodology uses two well-known opensource platforms - SAM (System Advisory Model) and IRENA FlexTool. Data for the energy capacity addition is obtained from SAM and optimization is done with FlexTool. A simple system is considered with a typical load profile and different energy sources. A few case scenarios are considered to demonstrate the effectiveness of the proposed approach and results are summarized.","PeriodicalId":224313,"journal":{"name":"2021 13th International Conference on Computational Intelligence and Communication Networks (CICN)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Duck Curve with Renewable Energies and Storage Technologies\",\"authors\":\"Giovani Manuel Pitra, Musti K. S. Sastry\",\"doi\":\"10.1109/CICN51697.2021.9574671\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Duck curve phenomena occurs when solar energy in higher quantities is integrated into the power grid. This results in excess generation that cannot be delivered during peak hours and a part of the load that cannot be supplied during off-peak hours. This paper proposes a novel, 2-step methodology to determine the effects of duck curve and also to flatten the same. This methodology uses two well-known opensource platforms - SAM (System Advisory Model) and IRENA FlexTool. Data for the energy capacity addition is obtained from SAM and optimization is done with FlexTool. A simple system is considered with a typical load profile and different energy sources. A few case scenarios are considered to demonstrate the effectiveness of the proposed approach and results are summarized.\",\"PeriodicalId\":224313,\"journal\":{\"name\":\"2021 13th International Conference on Computational Intelligence and Communication Networks (CICN)\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 13th International Conference on Computational Intelligence and Communication Networks (CICN)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CICN51697.2021.9574671\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 13th International Conference on Computational Intelligence and Communication Networks (CICN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CICN51697.2021.9574671","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

当大量太阳能并网时,会出现鸭曲线现象。这导致在高峰时段无法提供多余的发电量,并且在非高峰时段无法提供部分负载。本文提出了一种新的两步方法来确定鸭曲线的影响,并使其变平。该方法使用了两个著名的开源平台——SAM(系统咨询模型)和IRENA FlexTool。能量容量增加数据由SAM获取,并利用FlexTool进行优化。考虑一个具有典型负荷分布和不同能源的简单系统。本文考虑了几个案例来证明所提出方法的有效性,并对结果进行了总结。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Duck Curve with Renewable Energies and Storage Technologies
Duck curve phenomena occurs when solar energy in higher quantities is integrated into the power grid. This results in excess generation that cannot be delivered during peak hours and a part of the load that cannot be supplied during off-peak hours. This paper proposes a novel, 2-step methodology to determine the effects of duck curve and also to flatten the same. This methodology uses two well-known opensource platforms - SAM (System Advisory Model) and IRENA FlexTool. Data for the energy capacity addition is obtained from SAM and optimization is done with FlexTool. A simple system is considered with a typical load profile and different energy sources. A few case scenarios are considered to demonstrate the effectiveness of the proposed approach and results are summarized.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信