毛细管驱动流动在圆形微通道内液气界面位置的理论与数值研究

Arshya Bamshad, A. Nikfarjam, M. Sabour, H. Raji
{"title":"毛细管驱动流动在圆形微通道内液气界面位置的理论与数值研究","authors":"Arshya Bamshad, A. Nikfarjam, M. Sabour, H. Raji","doi":"10.1109/ICROM.2017.8466144","DOIUrl":null,"url":null,"abstract":"The main aim of this study is to find the best, most rapid, and the most accurate numerical method to find the liquid-gas interface of capillary driven flow during the time in circular Microchannels by using COMSOL Multiphysics software. Capillary driven flow by eliminating micropumps or any physical pressure gradient generators can make the microfluidic devices cheaper and more usable. Hence, by using this two-phase flow, the final costs of lots of microfluidic devices and lab-on-a-chip can significantly be decreased and help them to be commercialized. The first step to employing the capillary flow in these devices is the simulation of this flow inside the microchannels. One of the most common and valid software for this work is COMSOL Multiphysics; this fact reveals the importance of this study. In this research study, simulation results obtained by using two possible numerical methods in this software, for capillary flows of water and ethanol in two different circular micro channels, verified and compared with four other methods, which verified experimentally before. Finally, the most accurate and time-saving numerical method of this software will be specified. This appropriate technique can contribute to simulate microfluidic and lab-on-a-chip devices, which are made of different mechanical and electrical parts, in COMSOL Multiphysics software by choosing the best method.","PeriodicalId":166992,"journal":{"name":"2017 5th RSI International Conference on Robotics and Mechatronics (ICRoM)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Theoretical and Numerical Investigation of Liquid-Gas Interface Location of Capillary Driven Flow During the Time Throughout Circular Microchannels\",\"authors\":\"Arshya Bamshad, A. Nikfarjam, M. Sabour, H. Raji\",\"doi\":\"10.1109/ICROM.2017.8466144\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main aim of this study is to find the best, most rapid, and the most accurate numerical method to find the liquid-gas interface of capillary driven flow during the time in circular Microchannels by using COMSOL Multiphysics software. Capillary driven flow by eliminating micropumps or any physical pressure gradient generators can make the microfluidic devices cheaper and more usable. Hence, by using this two-phase flow, the final costs of lots of microfluidic devices and lab-on-a-chip can significantly be decreased and help them to be commercialized. The first step to employing the capillary flow in these devices is the simulation of this flow inside the microchannels. One of the most common and valid software for this work is COMSOL Multiphysics; this fact reveals the importance of this study. In this research study, simulation results obtained by using two possible numerical methods in this software, for capillary flows of water and ethanol in two different circular micro channels, verified and compared with four other methods, which verified experimentally before. Finally, the most accurate and time-saving numerical method of this software will be specified. This appropriate technique can contribute to simulate microfluidic and lab-on-a-chip devices, which are made of different mechanical and electrical parts, in COMSOL Multiphysics software by choosing the best method.\",\"PeriodicalId\":166992,\"journal\":{\"name\":\"2017 5th RSI International Conference on Robotics and Mechatronics (ICRoM)\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 5th RSI International Conference on Robotics and Mechatronics (ICRoM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICROM.2017.8466144\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 5th RSI International Conference on Robotics and Mechatronics (ICRoM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICROM.2017.8466144","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本研究的主要目的是利用COMSOL Multiphysics软件,寻找最佳、最快速、最准确的计算圆形微通道内毛细管驱动流动时间内液气界面的数值方法。通过消除微泵或任何物理压力梯度发生器,毛细管驱动流可以使微流体装置更便宜,更实用。因此,通过使用这种两相流,可以大大降低许多微流控设备和芯片实验室的最终成本,并有助于它们的商业化。在这些设备中使用毛细管流动的第一步是模拟微通道内的毛细管流动。最常用和有效的软件之一是COMSOL Multiphysics;这一事实揭示了这项研究的重要性。在本研究中,本软件采用两种可能的数值方法对水和乙醇在两种不同的圆形微通道中的毛细管流动进行了模拟,并与之前实验验证的其他四种方法进行了验证和比较。最后给出了该软件最精确、最省时的数值计算方法。在COMSOL Multiphysics软件中,通过选择合适的方法,可以模拟由不同机械和电气部件组成的微流体和片上实验室设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Theoretical and Numerical Investigation of Liquid-Gas Interface Location of Capillary Driven Flow During the Time Throughout Circular Microchannels
The main aim of this study is to find the best, most rapid, and the most accurate numerical method to find the liquid-gas interface of capillary driven flow during the time in circular Microchannels by using COMSOL Multiphysics software. Capillary driven flow by eliminating micropumps or any physical pressure gradient generators can make the microfluidic devices cheaper and more usable. Hence, by using this two-phase flow, the final costs of lots of microfluidic devices and lab-on-a-chip can significantly be decreased and help them to be commercialized. The first step to employing the capillary flow in these devices is the simulation of this flow inside the microchannels. One of the most common and valid software for this work is COMSOL Multiphysics; this fact reveals the importance of this study. In this research study, simulation results obtained by using two possible numerical methods in this software, for capillary flows of water and ethanol in two different circular micro channels, verified and compared with four other methods, which verified experimentally before. Finally, the most accurate and time-saving numerical method of this software will be specified. This appropriate technique can contribute to simulate microfluidic and lab-on-a-chip devices, which are made of different mechanical and electrical parts, in COMSOL Multiphysics software by choosing the best method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信