E. Ormond, M. Parrales, Michael R. Garcia, John R. Smith, P. H. Amos, K. Hogge, M. Misch, Mohammed Mohammed, H. Truong
{"title":"天鹅座系统定时","authors":"E. Ormond, M. Parrales, Michael R. Garcia, John R. Smith, P. H. Amos, K. Hogge, M. Misch, Mohammed Mohammed, H. Truong","doi":"10.1109/PPPS34859.2019.9009664","DOIUrl":null,"url":null,"abstract":"The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources each with a dose rating of 4-rad at 1 m, and a 1-mm diameter spot size. The development of the rod pinch diode was responsible for the ability to meet these criteria1. The rod pinch diode in a Cygnus machine uses a 0.75-mm diameter, tapered tip, tungsten anode rod extended through a 9-mm diameter, aluminum cathode aperture. When properly configured, the electron beam born off the aperture edge can self-insulate and pinch onto the tip of the rod creating an intense, small x-ray source. The Cygnus sources are utilized as the primary diagnostic on Subcritical Experiments that are single-shot, high-value events. The system timing on Cygnus will be evaluated as related to the following system elements: HV trigger generator, Marx, pulse forming line and rod pinch diode. Spare trigger generators will also be included in this evaluation.","PeriodicalId":103240,"journal":{"name":"2019 IEEE Pulsed Power & Plasma Science (PPPS)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cygnus System Timing\",\"authors\":\"E. Ormond, M. Parrales, Michael R. Garcia, John R. Smith, P. H. Amos, K. Hogge, M. Misch, Mohammed Mohammed, H. Truong\",\"doi\":\"10.1109/PPPS34859.2019.9009664\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources each with a dose rating of 4-rad at 1 m, and a 1-mm diameter spot size. The development of the rod pinch diode was responsible for the ability to meet these criteria1. The rod pinch diode in a Cygnus machine uses a 0.75-mm diameter, tapered tip, tungsten anode rod extended through a 9-mm diameter, aluminum cathode aperture. When properly configured, the electron beam born off the aperture edge can self-insulate and pinch onto the tip of the rod creating an intense, small x-ray source. The Cygnus sources are utilized as the primary diagnostic on Subcritical Experiments that are single-shot, high-value events. The system timing on Cygnus will be evaluated as related to the following system elements: HV trigger generator, Marx, pulse forming line and rod pinch diode. Spare trigger generators will also be included in this evaluation.\",\"PeriodicalId\":103240,\"journal\":{\"name\":\"2019 IEEE Pulsed Power & Plasma Science (PPPS)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Pulsed Power & Plasma Science (PPPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPPS34859.2019.9009664\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Pulsed Power & Plasma Science (PPPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPPS34859.2019.9009664","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources each with a dose rating of 4-rad at 1 m, and a 1-mm diameter spot size. The development of the rod pinch diode was responsible for the ability to meet these criteria1. The rod pinch diode in a Cygnus machine uses a 0.75-mm diameter, tapered tip, tungsten anode rod extended through a 9-mm diameter, aluminum cathode aperture. When properly configured, the electron beam born off the aperture edge can self-insulate and pinch onto the tip of the rod creating an intense, small x-ray source. The Cygnus sources are utilized as the primary diagnostic on Subcritical Experiments that are single-shot, high-value events. The system timing on Cygnus will be evaluated as related to the following system elements: HV trigger generator, Marx, pulse forming line and rod pinch diode. Spare trigger generators will also be included in this evaluation.