光学仪器变压器特性对保护继电器和电能质量表性能的影响

M. Kezunovic, L. Portillo, G. Karady, S. Kucuksari
{"title":"光学仪器变压器特性对保护继电器和电能质量表性能的影响","authors":"M. Kezunovic, L. Portillo, G. Karady, S. Kucuksari","doi":"10.1109/TDCLA.2006.311597","DOIUrl":null,"url":null,"abstract":"This paper evaluates the influence of optical instrument transformers (OIT) characteristics on the performance of protection and power quality metering intelligent electronic devices (IED). Lab research and experience from field application have shown that instrument transformer characteristics may affect the performance of relays, revenue metering systems and power quality meters. Recently, optical voltage and current instrument transformers have become readily available. Optical transducers measure changes in properties of some materials as a result of the surrounding electrical or magnetic field instead of directly measuring currents and voltages. A quantitative relationship between this change and the current or voltage can be obtained. OIT provide several benefits for protection and metering applications: wider frequency bandwidth and better dynamic performance. A previous study has presented a methodology for assessing the influence of instrument transformer characteristics on relay performance. The methodology presented in this paper uses some of the aspects presented in the previous studies and defines criteria and procedure for evaluating the influence of OIT characteristics on the performance protective relays and power quality meters. OIT models obtained from laboratory testing of actual sensors have been used along with simulation environment to quantify the influence. Results of simulation are presented","PeriodicalId":406067,"journal":{"name":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Impact of Optical Instrument Transformer Characteristics on the Performance of Protective Relays and Power Quality Meters\",\"authors\":\"M. Kezunovic, L. Portillo, G. Karady, S. Kucuksari\",\"doi\":\"10.1109/TDCLA.2006.311597\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper evaluates the influence of optical instrument transformers (OIT) characteristics on the performance of protection and power quality metering intelligent electronic devices (IED). Lab research and experience from field application have shown that instrument transformer characteristics may affect the performance of relays, revenue metering systems and power quality meters. Recently, optical voltage and current instrument transformers have become readily available. Optical transducers measure changes in properties of some materials as a result of the surrounding electrical or magnetic field instead of directly measuring currents and voltages. A quantitative relationship between this change and the current or voltage can be obtained. OIT provide several benefits for protection and metering applications: wider frequency bandwidth and better dynamic performance. A previous study has presented a methodology for assessing the influence of instrument transformer characteristics on relay performance. The methodology presented in this paper uses some of the aspects presented in the previous studies and defines criteria and procedure for evaluating the influence of OIT characteristics on the performance protective relays and power quality meters. OIT models obtained from laboratory testing of actual sensors have been used along with simulation environment to quantify the influence. Results of simulation are presented\",\"PeriodicalId\":406067,\"journal\":{\"name\":\"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDCLA.2006.311597\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDCLA.2006.311597","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

本文评价了光学仪器变压器(OIT)特性对保护和电能质量计量智能电子设备(IED)性能的影响。实验室研究和现场应用的经验表明,仪表变压器的特性可能会影响继电器、收入计量系统和电能质量表的性能。最近,光学电压和电流互感器已经变得很容易获得。光学换能器不是直接测量电流和电压,而是根据周围的电场或磁场来测量某些材料性质的变化。这种变化与电流或电压之间的定量关系可以得到。OIT为保护和计量应用提供了几个好处:更宽的频率带宽和更好的动态性能。先前的研究提出了一种评估仪表变压器特性对继电器性能影响的方法。本文提出的方法借鉴了以往研究的一些方面,并定义了评估OIT特性对性能保护继电器和电能质量计的影响的标准和程序。通过实际传感器的实验室测试获得的OIT模型与仿真环境一起用于量化影响。给出了仿真结果
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of Optical Instrument Transformer Characteristics on the Performance of Protective Relays and Power Quality Meters
This paper evaluates the influence of optical instrument transformers (OIT) characteristics on the performance of protection and power quality metering intelligent electronic devices (IED). Lab research and experience from field application have shown that instrument transformer characteristics may affect the performance of relays, revenue metering systems and power quality meters. Recently, optical voltage and current instrument transformers have become readily available. Optical transducers measure changes in properties of some materials as a result of the surrounding electrical or magnetic field instead of directly measuring currents and voltages. A quantitative relationship between this change and the current or voltage can be obtained. OIT provide several benefits for protection and metering applications: wider frequency bandwidth and better dynamic performance. A previous study has presented a methodology for assessing the influence of instrument transformer characteristics on relay performance. The methodology presented in this paper uses some of the aspects presented in the previous studies and defines criteria and procedure for evaluating the influence of OIT characteristics on the performance protective relays and power quality meters. OIT models obtained from laboratory testing of actual sensors have been used along with simulation environment to quantify the influence. Results of simulation are presented
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信