用于放射性核素功能分子成像的高分辨率和高灵敏度探测器:闪烁体像素大小、光电探测器阳极间距、准直技术和读数的作用

F. Garibaldi, R. Accorsi, M. Cinti, E. Cisbani, S. Colilli, F. Cusanno, R. Fratoni, F. Giuliani, M. Gricia, R. Lanza, S. Meo, M. Lucentini, S. Majewski, R. Pani, R. Pellegrini, F. Santavenere, B. M. W. Tsui
{"title":"用于放射性核素功能分子成像的高分辨率和高灵敏度探测器:闪烁体像素大小、光电探测器阳极间距、准直技术和读数的作用","authors":"F. Garibaldi, R. Accorsi, M. Cinti, E. Cisbani, S. Colilli, F. Cusanno, R. Fratoni, F. Giuliani, M. Gricia, R. Lanza, S. Meo, M. Lucentini, S. Majewski, R. Pani, R. Pellegrini, F. Santavenere, B. M. W. Tsui","doi":"10.1109/NSSMIC.2005.1596919","DOIUrl":null,"url":null,"abstract":"Good spatial resolution and high sensitivity are required for detectors to be used for most of the bio-medical research and application (small animal imaging, detection of small tumors). In this paper we report on parameter optimization of single photon gamma rays detectors. Simulations and measurements were performed for designing and building detectors for early detection of small tumors in breast and in small animal imaging. Critical parameters are: contrast and signal to noise ratio (SNR). Intrinsic performances (spatial resolution, pixel identification etc.) were optimized first. Arrays of scintillators (NaI(Tl)) of different pixel pitch (down to the present technological limits for NaI(Tl) arrays fabrication (pitch of 2times2 mm2, 1.5times1.5 mm2 and 1.2times1.2 mm2 )) were coupled to arrays of PSPMTs with two anode readout element dimensions (6times6 mm2 and 3times3 mm2). Detectors having field of view of 100times100 mm2 and 150times200 mm2 were designed and built. An electronics system for reading out all the anode pad signals has been designed and constructed. Finally the collimation technique was considered. The limits of the coded aperture option have been studied. Preliminary results of these studies are presented","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"High resolution and high sensitivity detectors for functional molecular imaging with radionuclides: the role of scintillator pixel size, photodetector anode pitch, collimation technique, and of the readout\",\"authors\":\"F. Garibaldi, R. Accorsi, M. Cinti, E. Cisbani, S. Colilli, F. Cusanno, R. Fratoni, F. Giuliani, M. Gricia, R. Lanza, S. Meo, M. Lucentini, S. Majewski, R. Pani, R. Pellegrini, F. Santavenere, B. M. W. Tsui\",\"doi\":\"10.1109/NSSMIC.2005.1596919\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Good spatial resolution and high sensitivity are required for detectors to be used for most of the bio-medical research and application (small animal imaging, detection of small tumors). In this paper we report on parameter optimization of single photon gamma rays detectors. Simulations and measurements were performed for designing and building detectors for early detection of small tumors in breast and in small animal imaging. Critical parameters are: contrast and signal to noise ratio (SNR). Intrinsic performances (spatial resolution, pixel identification etc.) were optimized first. Arrays of scintillators (NaI(Tl)) of different pixel pitch (down to the present technological limits for NaI(Tl) arrays fabrication (pitch of 2times2 mm2, 1.5times1.5 mm2 and 1.2times1.2 mm2 )) were coupled to arrays of PSPMTs with two anode readout element dimensions (6times6 mm2 and 3times3 mm2). Detectors having field of view of 100times100 mm2 and 150times200 mm2 were designed and built. An electronics system for reading out all the anode pad signals has been designed and constructed. Finally the collimation technique was considered. The limits of the coded aperture option have been studied. Preliminary results of these studies are presented\",\"PeriodicalId\":105619,\"journal\":{\"name\":\"IEEE Nuclear Science Symposium Conference Record, 2005\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposium Conference Record, 2005\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2005.1596919\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium Conference Record, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2005.1596919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

大多数生物医学研究和应用(小动物成像、小肿瘤检测)都要求探测器具有良好的空间分辨率和高灵敏度。本文报道了单光子伽马射线探测器的参数优化。模拟和测量进行了设计和构建探测器早期检测乳腺小肿瘤和小动物成像。关键参数是:对比度和信噪比(SNR)。首先对其内在性能(空间分辨率、像素识别等)进行优化。不同像素间距的闪烁体(NaI(Tl))阵列(降低到目前NaI(Tl)阵列制造的技术极限(间距为2times2 mm2, 1.5times1.5 mm2和1.2times1.2 mm2))与具有两个阳极读出元件尺寸(6times6 mm2和3times3 mm2)的pspmt阵列耦合。设计并制造了视场为100 × 100 mm2和150 × 200 mm2的探测器。设计并构建了一个读取所有阳极衬垫信号的电子系统。最后考虑了准直技术。研究了编码孔径选择的局限性。本文给出了这些研究的初步结果
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High resolution and high sensitivity detectors for functional molecular imaging with radionuclides: the role of scintillator pixel size, photodetector anode pitch, collimation technique, and of the readout
Good spatial resolution and high sensitivity are required for detectors to be used for most of the bio-medical research and application (small animal imaging, detection of small tumors). In this paper we report on parameter optimization of single photon gamma rays detectors. Simulations and measurements were performed for designing and building detectors for early detection of small tumors in breast and in small animal imaging. Critical parameters are: contrast and signal to noise ratio (SNR). Intrinsic performances (spatial resolution, pixel identification etc.) were optimized first. Arrays of scintillators (NaI(Tl)) of different pixel pitch (down to the present technological limits for NaI(Tl) arrays fabrication (pitch of 2times2 mm2, 1.5times1.5 mm2 and 1.2times1.2 mm2 )) were coupled to arrays of PSPMTs with two anode readout element dimensions (6times6 mm2 and 3times3 mm2). Detectors having field of view of 100times100 mm2 and 150times200 mm2 were designed and built. An electronics system for reading out all the anode pad signals has been designed and constructed. Finally the collimation technique was considered. The limits of the coded aperture option have been studied. Preliminary results of these studies are presented
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信