微处理器控制的PWM逆变器用于正弦输出

K. Jezernik, M. Milanović, D. Zadravec
{"title":"微处理器控制的PWM逆变器用于正弦输出","authors":"K. Jezernik, M. Milanović, D. Zadravec","doi":"10.1109/MELCON.1989.49978","DOIUrl":null,"url":null,"abstract":"The authors describe and analyze two PWM (pulse width modulation) control methods for UPS (uninterruptible power supply) systems. The first method is hysteresis control with a single measure value. The second method is microprocessor-based constant-frequency PWM with a dead-beat controller. Simulation results are presented for a single-phase UPS and a three-phase UPS with a DY transformer using the latter method. It is noted that UPS systems with hysteresis controllers, because of finite turn-on and turn-off times and finite hysteresis width, require a differentiator which is very difficult to implement. PWM with a dead-beat controller has a constant switch frequency; at a switch frequency of 2 kHz, better results were achieved using a smaller LC filter.<<ETX>>","PeriodicalId":380214,"journal":{"name":"Proceedings. Electrotechnical Conference Integrating Research, Industry and Education in Energy and Communication Engineering',","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Microprocessor control of PWM inverter for sinusoidal output\",\"authors\":\"K. Jezernik, M. Milanović, D. Zadravec\",\"doi\":\"10.1109/MELCON.1989.49978\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors describe and analyze two PWM (pulse width modulation) control methods for UPS (uninterruptible power supply) systems. The first method is hysteresis control with a single measure value. The second method is microprocessor-based constant-frequency PWM with a dead-beat controller. Simulation results are presented for a single-phase UPS and a three-phase UPS with a DY transformer using the latter method. It is noted that UPS systems with hysteresis controllers, because of finite turn-on and turn-off times and finite hysteresis width, require a differentiator which is very difficult to implement. PWM with a dead-beat controller has a constant switch frequency; at a switch frequency of 2 kHz, better results were achieved using a smaller LC filter.<<ETX>>\",\"PeriodicalId\":380214,\"journal\":{\"name\":\"Proceedings. Electrotechnical Conference Integrating Research, Industry and Education in Energy and Communication Engineering',\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. Electrotechnical Conference Integrating Research, Industry and Education in Energy and Communication Engineering',\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MELCON.1989.49978\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. Electrotechnical Conference Integrating Research, Industry and Education in Energy and Communication Engineering',","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MELCON.1989.49978","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

对不间断电源系统的两种脉宽调制(PWM)控制方法进行了描述和分析。第一种方法是用单个测量值进行迟滞控制。第二种方法是基于微处理器的带死拍控制器的恒频PWM。采用后一种方法给出了单相UPS和带DY变压器的三相UPS的仿真结果。需要注意的是,具有迟滞控制器的UPS系统,由于有限的接通和关断时间以及有限的迟滞宽度,需要一个很难实现的微分器。带死拍控制器的PWM具有恒定的开关频率;在2 kHz的开关频率下,使用较小的LC滤波器可以获得更好的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Microprocessor control of PWM inverter for sinusoidal output
The authors describe and analyze two PWM (pulse width modulation) control methods for UPS (uninterruptible power supply) systems. The first method is hysteresis control with a single measure value. The second method is microprocessor-based constant-frequency PWM with a dead-beat controller. Simulation results are presented for a single-phase UPS and a three-phase UPS with a DY transformer using the latter method. It is noted that UPS systems with hysteresis controllers, because of finite turn-on and turn-off times and finite hysteresis width, require a differentiator which is very difficult to implement. PWM with a dead-beat controller has a constant switch frequency; at a switch frequency of 2 kHz, better results were achieved using a smaller LC filter.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信