F. Cutolo, S. Carli, P. Parchi, Luca Canalini, M. Ferrari, M. Lisanti, V. Ferrari
{"title":"AR相互作用模式在长骨骨折外固定术闭合复位中的应用","authors":"F. Cutolo, S. Carli, P. Parchi, Luca Canalini, M. Ferrari, M. Lisanti, V. Ferrari","doi":"10.1145/2993369.2996317","DOIUrl":null,"url":null,"abstract":"We present an intuitive and ergonomic AR strategy to be coupled with a standard external fixation system aimed at aiding the accurate closed reduction of long-bone shaft fractures. The correct six DOF alignment between the bone fragments can be retrieved by manually repositioning a pair of reference frames constrained to the two extremities of the fixator so as to minimize the geometric distance, on the image plane, between planned/virtual landmarks and their observed/real counterparts. The reduction accuracy was positively validated in vitro in a pilot study that involved an orthopedic surgeon.","PeriodicalId":396801,"journal":{"name":"Proceedings of the 22nd ACM Conference on Virtual Reality Software and Technology","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"AR interaction paradigm for closed reduction of long-bone fractures via external fixation\",\"authors\":\"F. Cutolo, S. Carli, P. Parchi, Luca Canalini, M. Ferrari, M. Lisanti, V. Ferrari\",\"doi\":\"10.1145/2993369.2996317\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present an intuitive and ergonomic AR strategy to be coupled with a standard external fixation system aimed at aiding the accurate closed reduction of long-bone shaft fractures. The correct six DOF alignment between the bone fragments can be retrieved by manually repositioning a pair of reference frames constrained to the two extremities of the fixator so as to minimize the geometric distance, on the image plane, between planned/virtual landmarks and their observed/real counterparts. The reduction accuracy was positively validated in vitro in a pilot study that involved an orthopedic surgeon.\",\"PeriodicalId\":396801,\"journal\":{\"name\":\"Proceedings of the 22nd ACM Conference on Virtual Reality Software and Technology\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 22nd ACM Conference on Virtual Reality Software and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/2993369.2996317\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 22nd ACM Conference on Virtual Reality Software and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2993369.2996317","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
AR interaction paradigm for closed reduction of long-bone fractures via external fixation
We present an intuitive and ergonomic AR strategy to be coupled with a standard external fixation system aimed at aiding the accurate closed reduction of long-bone shaft fractures. The correct six DOF alignment between the bone fragments can be retrieved by manually repositioning a pair of reference frames constrained to the two extremities of the fixator so as to minimize the geometric distance, on the image plane, between planned/virtual landmarks and their observed/real counterparts. The reduction accuracy was positively validated in vitro in a pilot study that involved an orthopedic surgeon.