{"title":"扭曲网格中填充u型单元的无传感器控制","authors":"Ying He, Po Li","doi":"10.1109/SPIES52282.2021.9633861","DOIUrl":null,"url":null,"abstract":"With the trend of distorted changes in the power grid, controlling the converter to achieve high-performance access to the grid under distorted power grids has become a problem worthy of attention. This paper uses Packed-U-Cells as the research topology. In the absence of a grid voltage sensor, the harmonic detection link is used to reconstruct the accurate grid voltage signal, and the FCS MPC method is combined to realize the tracking of the reference grid current. The simulation based on MATLAB/Simulink and the experimental results based on Hardware-In-the-Loop all prove the reliability of the proposed control system.","PeriodicalId":411512,"journal":{"name":"2021 3rd International Conference on Smart Power & Internet Energy Systems (SPIES)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sensorless Control of Packed-U-Cells in Distorted Grid\",\"authors\":\"Ying He, Po Li\",\"doi\":\"10.1109/SPIES52282.2021.9633861\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the trend of distorted changes in the power grid, controlling the converter to achieve high-performance access to the grid under distorted power grids has become a problem worthy of attention. This paper uses Packed-U-Cells as the research topology. In the absence of a grid voltage sensor, the harmonic detection link is used to reconstruct the accurate grid voltage signal, and the FCS MPC method is combined to realize the tracking of the reference grid current. The simulation based on MATLAB/Simulink and the experimental results based on Hardware-In-the-Loop all prove the reliability of the proposed control system.\",\"PeriodicalId\":411512,\"journal\":{\"name\":\"2021 3rd International Conference on Smart Power & Internet Energy Systems (SPIES)\",\"volume\":\"54 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 3rd International Conference on Smart Power & Internet Energy Systems (SPIES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPIES52282.2021.9633861\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 3rd International Conference on Smart Power & Internet Energy Systems (SPIES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPIES52282.2021.9633861","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
随着电网畸变变化的趋势,控制变流器在畸变电网下实现高性能入网已成为一个值得关注的问题。本文采用了pack - u - cells作为研究拓扑。在没有电网电压传感器的情况下,利用谐波检测环节重构准确的电网电压信号,并结合FCS - MPC方法实现对参考电网电流的跟踪。基于MATLAB/Simulink的仿真和基于硬件在环的实验结果都证明了所提控制系统的可靠性。
Sensorless Control of Packed-U-Cells in Distorted Grid
With the trend of distorted changes in the power grid, controlling the converter to achieve high-performance access to the grid under distorted power grids has become a problem worthy of attention. This paper uses Packed-U-Cells as the research topology. In the absence of a grid voltage sensor, the harmonic detection link is used to reconstruct the accurate grid voltage signal, and the FCS MPC method is combined to realize the tracking of the reference grid current. The simulation based on MATLAB/Simulink and the experimental results based on Hardware-In-the-Loop all prove the reliability of the proposed control system.