NRC锶单离子频率标准作为光学原子钟的评价与运行进展

A. Madej, P. Dubé, J. Bernard, G. Humphrey, M. Vainio, J. Jiang, D.J. Jones
{"title":"NRC锶单离子频率标准作为光学原子钟的评价与运行进展","authors":"A. Madej, P. Dubé, J. Bernard, G. Humphrey, M. Vainio, J. Jiang, D.J. Jones","doi":"10.1109/CPEM.2010.5544362","DOIUrl":null,"url":null,"abstract":"Improved functionality and accuracy of the NRC Sr+ single trapped ion 445-THz standard is described. Absolute frequency stabilization of all laser sources has been achieved together with loading of the ion trap using photo-ionization methods. An Erbium fiber laser based frequency comb is used to directly measure the 445-THz clock frequency. A 9 hr preliminary measurement was performed with statistical uncertainty of 1.4 Hz (3×10−15) in excellent agreement with a previously reported value in 2005. A new endcap trap with probing and micromotion correction in three dimensions has been assembled and will have uncertainties approaching 10−17 in the near future.","PeriodicalId":222495,"journal":{"name":"CPEM 2010","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Progress in the evaluation and operation of the NRC strontium single ion frequency standard as an optical atomic clock\",\"authors\":\"A. Madej, P. Dubé, J. Bernard, G. Humphrey, M. Vainio, J. Jiang, D.J. Jones\",\"doi\":\"10.1109/CPEM.2010.5544362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Improved functionality and accuracy of the NRC Sr+ single trapped ion 445-THz standard is described. Absolute frequency stabilization of all laser sources has been achieved together with loading of the ion trap using photo-ionization methods. An Erbium fiber laser based frequency comb is used to directly measure the 445-THz clock frequency. A 9 hr preliminary measurement was performed with statistical uncertainty of 1.4 Hz (3×10−15) in excellent agreement with a previously reported value in 2005. A new endcap trap with probing and micromotion correction in three dimensions has been assembled and will have uncertainties approaching 10−17 in the near future.\",\"PeriodicalId\":222495,\"journal\":{\"name\":\"CPEM 2010\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CPEM 2010\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2010.5544362\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CPEM 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2010.5544362","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

描述了NRC Sr+单捕获离子445-THz标准的改进功能和准确性。所有激光源的绝对频率稳定已经实现,并与离子阱加载使用光电离方法。利用铒光纤激光频率梳直接测量445thz时钟频率。进行了9小时的初步测量,统计不确定度为1.4 Hz (3×10−15),与2005年先前报道的值非常吻合。一个具有三维探测和微运动校正的新端盖陷阱已经组装完成,在不久的将来,其不确定度将接近10 - 17。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Progress in the evaluation and operation of the NRC strontium single ion frequency standard as an optical atomic clock
Improved functionality and accuracy of the NRC Sr+ single trapped ion 445-THz standard is described. Absolute frequency stabilization of all laser sources has been achieved together with loading of the ion trap using photo-ionization methods. An Erbium fiber laser based frequency comb is used to directly measure the 445-THz clock frequency. A 9 hr preliminary measurement was performed with statistical uncertainty of 1.4 Hz (3×10−15) in excellent agreement with a previously reported value in 2005. A new endcap trap with probing and micromotion correction in three dimensions has been assembled and will have uncertainties approaching 10−17 in the near future.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信