基于温度传感数据的艾灸装置温控特性分析

Taegon Kim, M. Cheon
{"title":"基于温度传感数据的艾灸装置温控特性分析","authors":"Taegon Kim, M. Cheon","doi":"10.1504/IJSTM.2017.10002699","DOIUrl":null,"url":null,"abstract":"In this study, a moxibustion device was developed using a silicone heater for safe and effective use. The developed moxibustion device is divided into a control unit in charge of overall control of the apparatus and a care unit to transfer heat and extract to the treated part. The device uses an infrared temperature sensor installed in the care units for real-time detection of the change in the skin surface temperature using a heater, so that it always follows the setting temperature. Moreover, to implement various heating patterns, the constant voltage applied to the heater was adjusted using voltage regulator (VR). As a result, the constant voltage applied to the object changed according to the variation in the VR. According to the measurement of the skin temperature, the heat was uniformly transferred to the affected parts.","PeriodicalId":171228,"journal":{"name":"Int. J. Serv. Technol. Manag.","volume":"116 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis on the thermo-control characteristics of moxibustion device based on temperature sensing data\",\"authors\":\"Taegon Kim, M. Cheon\",\"doi\":\"10.1504/IJSTM.2017.10002699\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, a moxibustion device was developed using a silicone heater for safe and effective use. The developed moxibustion device is divided into a control unit in charge of overall control of the apparatus and a care unit to transfer heat and extract to the treated part. The device uses an infrared temperature sensor installed in the care units for real-time detection of the change in the skin surface temperature using a heater, so that it always follows the setting temperature. Moreover, to implement various heating patterns, the constant voltage applied to the heater was adjusted using voltage regulator (VR). As a result, the constant voltage applied to the object changed according to the variation in the VR. According to the measurement of the skin temperature, the heat was uniformly transferred to the affected parts.\",\"PeriodicalId\":171228,\"journal\":{\"name\":\"Int. J. Serv. Technol. Manag.\",\"volume\":\"116 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-02-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Int. J. Serv. Technol. Manag.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1504/IJSTM.2017.10002699\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Int. J. Serv. Technol. Manag.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/IJSTM.2017.10002699","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了安全有效的使用,本研究开发了一种使用硅胶加热器的艾灸装置。本发明的艾灸装置分为控制单元和护理单元,控制单元负责对装置进行整体控制,护理单元负责向被治疗部位传递热量和提取。该设备使用安装在护理单元内的红外温度传感器,通过加热器实时检测皮肤表面温度的变化,使其始终遵循设定温度。此外,为了实现各种加热模式,使用电压调节器(VR)调节施加在加热器上的恒定电压。因此,施加在物体上的恒定电压会根据VR的变化而变化。根据测得的皮肤温度,将热量均匀地传递到受热部位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis on the thermo-control characteristics of moxibustion device based on temperature sensing data
In this study, a moxibustion device was developed using a silicone heater for safe and effective use. The developed moxibustion device is divided into a control unit in charge of overall control of the apparatus and a care unit to transfer heat and extract to the treated part. The device uses an infrared temperature sensor installed in the care units for real-time detection of the change in the skin surface temperature using a heater, so that it always follows the setting temperature. Moreover, to implement various heating patterns, the constant voltage applied to the heater was adjusted using voltage regulator (VR). As a result, the constant voltage applied to the object changed according to the variation in the VR. According to the measurement of the skin temperature, the heat was uniformly transferred to the affected parts.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信