{"title":"现代配电系统故障定位方法的评价方法","authors":"P. A. H. Cavalcante, M. D. de Almeida, J. M. Mora Flórez","doi":"10.1109/ISGT-LA.2015.7381153","DOIUrl":null,"url":null,"abstract":"This paper presents an approach to assess automatic fault location methods in power distribution systems. The proposed approach allows to consider the aleatory errors inherent to calculated, forecasted and measured values, typically required by the fault location methods for a more realistic and consistent evaluation. These errors can follow different mathematical distributions, according their source and the assumptions made. In order to demonstrate the proposed approach, a real power distribution system is considered, and additionally, one method that requires measurements at the power substation and one method that requires sparse voltage measurements are assessed.","PeriodicalId":345318,"journal":{"name":"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)","volume":"1986 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An approach to evaluate modern fault location methods for power distribution systems\",\"authors\":\"P. A. H. Cavalcante, M. D. de Almeida, J. M. Mora Flórez\",\"doi\":\"10.1109/ISGT-LA.2015.7381153\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an approach to assess automatic fault location methods in power distribution systems. The proposed approach allows to consider the aleatory errors inherent to calculated, forecasted and measured values, typically required by the fault location methods for a more realistic and consistent evaluation. These errors can follow different mathematical distributions, according their source and the assumptions made. In order to demonstrate the proposed approach, a real power distribution system is considered, and additionally, one method that requires measurements at the power substation and one method that requires sparse voltage measurements are assessed.\",\"PeriodicalId\":345318,\"journal\":{\"name\":\"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)\",\"volume\":\"1986 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGT-LA.2015.7381153\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-LA.2015.7381153","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了一种评估配电系统故障自动定位方法的方法。所提出的方法允许考虑计算、预测和测量值固有的偏差,通常需要故障定位方法进行更现实和一致的评估。根据它们的来源和所做的假设,这些误差可以遵循不同的数学分布。为了证明所提出的方法,考虑了一个真实的配电系统,另外,评估了一种需要在变电站测量的方法和一种需要稀疏电压测量的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An approach to evaluate modern fault location methods for power distribution systems
This paper presents an approach to assess automatic fault location methods in power distribution systems. The proposed approach allows to consider the aleatory errors inherent to calculated, forecasted and measured values, typically required by the fault location methods for a more realistic and consistent evaluation. These errors can follow different mathematical distributions, according their source and the assumptions made. In order to demonstrate the proposed approach, a real power distribution system is considered, and additionally, one method that requires measurements at the power substation and one method that requires sparse voltage measurements are assessed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信