{"title":"采用σ - δ A/D转换的电力电子变换器中的电压和电流传感","authors":"A. Mertens, D. Eckardt","doi":"10.1109/IAS.1996.560216","DOIUrl":null,"url":null,"abstract":"This paper presents a novel approach to voltage and current measurement in power electronics using a sigma-delta A/D converter. The system converts the analog input signal into a digital stream of data. By averaging the digital data stream over a switching period of the power converter, the required measurement is obtained. Harmonic distortion of the input waveform and noise caused by EMI is inherently filtered out. The analog part of the sigma-delta A/D converter is very simple and operates synchronously to a clock. This makes it possible to integrate the sigma-delta converter into a small ASIC. The stream of digital data at the output of the ASIC can be transmitted using a fibre optic link that also insulates the sensing point from control electronics, so that noninsulating sensors can be used.","PeriodicalId":177291,"journal":{"name":"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"29","resultStr":"{\"title\":\"Voltage and current sensing in power electronic converters using sigma-delta A/D conversion\",\"authors\":\"A. Mertens, D. Eckardt\",\"doi\":\"10.1109/IAS.1996.560216\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a novel approach to voltage and current measurement in power electronics using a sigma-delta A/D converter. The system converts the analog input signal into a digital stream of data. By averaging the digital data stream over a switching period of the power converter, the required measurement is obtained. Harmonic distortion of the input waveform and noise caused by EMI is inherently filtered out. The analog part of the sigma-delta A/D converter is very simple and operates synchronously to a clock. This makes it possible to integrate the sigma-delta converter into a small ASIC. The stream of digital data at the output of the ASIC can be transmitted using a fibre optic link that also insulates the sensing point from control electronics, so that noninsulating sensors can be used.\",\"PeriodicalId\":177291,\"journal\":{\"name\":\"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-10-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"29\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1996.560216\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1996.560216","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29
摘要
本文提出了一种利用σ - δ a /D转换器测量电力电子中电压和电流的新方法。该系统将模拟输入信号转换为数字数据流。通过对功率转换器开关周期内的数字数据流进行平均,可以得到所需的测量值。输入波形的谐波失真和电磁干扰引起的噪声被固有地滤除。σ - δ A/D转换器的模拟部分非常简单,与时钟同步操作。这使得将sigma-delta转换器集成到小型ASIC中成为可能。ASIC输出端的数字数据流可以使用光纤链路传输,该光纤链路还将传感点与控制电子设备隔离,因此可以使用非绝缘传感器。
Voltage and current sensing in power electronic converters using sigma-delta A/D conversion
This paper presents a novel approach to voltage and current measurement in power electronics using a sigma-delta A/D converter. The system converts the analog input signal into a digital stream of data. By averaging the digital data stream over a switching period of the power converter, the required measurement is obtained. Harmonic distortion of the input waveform and noise caused by EMI is inherently filtered out. The analog part of the sigma-delta A/D converter is very simple and operates synchronously to a clock. This makes it possible to integrate the sigma-delta converter into a small ASIC. The stream of digital data at the output of the ASIC can be transmitted using a fibre optic link that also insulates the sensing point from control electronics, so that noninsulating sensors can be used.