用肌电信号同时和比例控制二维手腕运动

J. Hahne, Hubertus Rehbaum, F. Biessmann, F. Meinecke, K. Müller, N. Jiang, D. Farina, L. Parra
{"title":"用肌电信号同时和比例控制二维手腕运动","authors":"J. Hahne, Hubertus Rehbaum, F. Biessmann, F. Meinecke, K. Müller, N. Jiang, D. Farina, L. Parra","doi":"10.1109/MLSP.2012.6349712","DOIUrl":null,"url":null,"abstract":"Previous approaches for extracting real-time proportional control information simultaneously for multiple degree of Freedom(DoF) from the electromyogram (EMG) often used non-linear methods such as the multilayer perceptron (MLP). In this pilot study we show that robust control is also possible with conventional linear regression if EMG power measures are available for a large number of electrodes. In particular, we show that it is possible to linearize the problem with simple nonlinear transformations of band-pass power. Because of its simplicity the method scales well to high dimensions, is easily regularized when insufficient training data is available, and is particularly well suited for real-time control as well as on-line optimization.","PeriodicalId":262601,"journal":{"name":"2012 IEEE International Workshop on Machine Learning for Signal Processing","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"34","resultStr":"{\"title\":\"Simultaneous and proportional control of 2D wrist movements with myoelectric signals\",\"authors\":\"J. Hahne, Hubertus Rehbaum, F. Biessmann, F. Meinecke, K. Müller, N. Jiang, D. Farina, L. Parra\",\"doi\":\"10.1109/MLSP.2012.6349712\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Previous approaches for extracting real-time proportional control information simultaneously for multiple degree of Freedom(DoF) from the electromyogram (EMG) often used non-linear methods such as the multilayer perceptron (MLP). In this pilot study we show that robust control is also possible with conventional linear regression if EMG power measures are available for a large number of electrodes. In particular, we show that it is possible to linearize the problem with simple nonlinear transformations of band-pass power. Because of its simplicity the method scales well to high dimensions, is easily regularized when insufficient training data is available, and is particularly well suited for real-time control as well as on-line optimization.\",\"PeriodicalId\":262601,\"journal\":{\"name\":\"2012 IEEE International Workshop on Machine Learning for Signal Processing\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"34\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Workshop on Machine Learning for Signal Processing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MLSP.2012.6349712\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Workshop on Machine Learning for Signal Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MLSP.2012.6349712","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 34

摘要

以往从肌电图中同时提取多自由度实时比例控制信息的方法通常采用非线性方法,如多层感知器(MLP)。在这项初步研究中,我们表明,如果肌电功率测量可用于大量电极,则传统线性回归也可以实现鲁棒控制。特别地,我们证明了用简单的带通功率非线性变换来线性化问题是可能的。由于其简单性,该方法可以很好地扩展到高维,当可用的训练数据不足时很容易正则化,并且特别适合于实时控制和在线优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simultaneous and proportional control of 2D wrist movements with myoelectric signals
Previous approaches for extracting real-time proportional control information simultaneously for multiple degree of Freedom(DoF) from the electromyogram (EMG) often used non-linear methods such as the multilayer perceptron (MLP). In this pilot study we show that robust control is also possible with conventional linear regression if EMG power measures are available for a large number of electrodes. In particular, we show that it is possible to linearize the problem with simple nonlinear transformations of band-pass power. Because of its simplicity the method scales well to high dimensions, is easily regularized when insufficient training data is available, and is particularly well suited for real-time control as well as on-line optimization.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信