正电子相机系统的简单数据丢失模型

L. Eriksson
{"title":"正电子相机系统的简单数据丢失模型","authors":"L. Eriksson","doi":"10.1109/NSSMIC.1993.373634","DOIUrl":null,"url":null,"abstract":"A simple model to describe data losses in PET cameras is presented. The model is not intended to be used primarily for dead time corrections in existing scanners, even if this may be possible. Instead the model is intended to be used for data simulations in order to determine the figures of merits of future camera systems based on data handling state-of-art solutions. The model assumes the data loss to be factorized into two components, one describing the detector or block-detector performance and the other the remaining data handling such as coincidence determinations, data transfer and data storage. Two modern positron camera systems have been investigated in terms of this model. These are the new Siemens-CTI systems, Ecat Exact and Ecat Exact HR, both with an axial field-of-view (FOV) covering around 15 cm. They both have retractable septa and can acquire data from the whole volume within the FOV and can reconstruct volume image data. An example is given how to use the model for live time calculations in a futuristic large axial FOV cylindrical system.<<ETX>>","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"104 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"42","resultStr":"{\"title\":\"A simple data loss model for positron camera systems\",\"authors\":\"L. Eriksson\",\"doi\":\"10.1109/NSSMIC.1993.373634\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple model to describe data losses in PET cameras is presented. The model is not intended to be used primarily for dead time corrections in existing scanners, even if this may be possible. Instead the model is intended to be used for data simulations in order to determine the figures of merits of future camera systems based on data handling state-of-art solutions. The model assumes the data loss to be factorized into two components, one describing the detector or block-detector performance and the other the remaining data handling such as coincidence determinations, data transfer and data storage. Two modern positron camera systems have been investigated in terms of this model. These are the new Siemens-CTI systems, Ecat Exact and Ecat Exact HR, both with an axial field-of-view (FOV) covering around 15 cm. They both have retractable septa and can acquire data from the whole volume within the FOV and can reconstruct volume image data. An example is given how to use the model for live time calculations in a futuristic large axial FOV cylindrical system.<<ETX>>\",\"PeriodicalId\":287813,\"journal\":{\"name\":\"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference\",\"volume\":\"104 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"42\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1993.373634\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1993.373634","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 42

摘要

提出了一个描述PET相机数据丢失的简单模型。该模型并不打算主要用于现有扫描仪中的死区时间校正,即使这是可能的。相反,该模型旨在用于数据模拟,以确定基于数据处理最先进解决方案的未来相机系统的优点。该模型假设将数据丢失分解为两个组件,一个描述检测器或块检测器的性能,另一个描述剩余的数据处理,如一致性确定、数据传输和数据存储。用这个模型研究了两个现代正电子相机系统。这些都是新的西门子- cti系统,Ecat Exact和Ecat Exact HR,都具有约15厘米的轴向视场(FOV)。它们都具有可伸缩的隔层,可以在视场内获取整个体的数据,并可以重建体图像数据。给出了如何将该模型用于未来大轴向视场柱面系统实时计算的实例
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A simple data loss model for positron camera systems
A simple model to describe data losses in PET cameras is presented. The model is not intended to be used primarily for dead time corrections in existing scanners, even if this may be possible. Instead the model is intended to be used for data simulations in order to determine the figures of merits of future camera systems based on data handling state-of-art solutions. The model assumes the data loss to be factorized into two components, one describing the detector or block-detector performance and the other the remaining data handling such as coincidence determinations, data transfer and data storage. Two modern positron camera systems have been investigated in terms of this model. These are the new Siemens-CTI systems, Ecat Exact and Ecat Exact HR, both with an axial field-of-view (FOV) covering around 15 cm. They both have retractable septa and can acquire data from the whole volume within the FOV and can reconstruct volume image data. An example is given how to use the model for live time calculations in a futuristic large axial FOV cylindrical system.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信