Tumiran, M. Wahyudi, N. A. Setiawan, K. Pambudi, Dharma Saputra
{"title":"基于紫外线辐射的污染和干燥条件下绝缘子的严重程度","authors":"Tumiran, M. Wahyudi, N. A. Setiawan, K. Pambudi, Dharma Saputra","doi":"10.1109/SPIES48661.2020.9242998","DOIUrl":null,"url":null,"abstract":"In this study, the ultraviolet (UV) emitted by partial discharge which occurred on the insulator in polluted and dry conditions was investigated. The UV image and intensity were recorded for 1 minute per voltage variation per pollutant weight variation. The voltage stress was varied until the flashover occurred. The results showed that there was no consistent relationship between pollutant weight and those two UV emission parameters. In addition, the UV intensity consisted of maximum, minimum, and average values because it fluctuated during the recording. There were two UV image patterns that could be identified, namely the scattered points and the concentrated light (forming an area). The greatest the UV intensity, the highest deviation between the maximum and minimum values, and the largest concentrated light pattern were found during a critical condition.","PeriodicalId":244426,"journal":{"name":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","volume":"95 6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Severity Level of An Insulator in Polluted and Dry Conditions Based on Ultraviolet Emission\",\"authors\":\"Tumiran, M. Wahyudi, N. A. Setiawan, K. Pambudi, Dharma Saputra\",\"doi\":\"10.1109/SPIES48661.2020.9242998\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, the ultraviolet (UV) emitted by partial discharge which occurred on the insulator in polluted and dry conditions was investigated. The UV image and intensity were recorded for 1 minute per voltage variation per pollutant weight variation. The voltage stress was varied until the flashover occurred. The results showed that there was no consistent relationship between pollutant weight and those two UV emission parameters. In addition, the UV intensity consisted of maximum, minimum, and average values because it fluctuated during the recording. There were two UV image patterns that could be identified, namely the scattered points and the concentrated light (forming an area). The greatest the UV intensity, the highest deviation between the maximum and minimum values, and the largest concentrated light pattern were found during a critical condition.\",\"PeriodicalId\":244426,\"journal\":{\"name\":\"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)\",\"volume\":\"95 6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPIES48661.2020.9242998\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPIES48661.2020.9242998","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Severity Level of An Insulator in Polluted and Dry Conditions Based on Ultraviolet Emission
In this study, the ultraviolet (UV) emitted by partial discharge which occurred on the insulator in polluted and dry conditions was investigated. The UV image and intensity were recorded for 1 minute per voltage variation per pollutant weight variation. The voltage stress was varied until the flashover occurred. The results showed that there was no consistent relationship between pollutant weight and those two UV emission parameters. In addition, the UV intensity consisted of maximum, minimum, and average values because it fluctuated during the recording. There were two UV image patterns that could be identified, namely the scattered points and the concentrated light (forming an area). The greatest the UV intensity, the highest deviation between the maximum and minimum values, and the largest concentrated light pattern were found during a critical condition.