基于紫外线辐射的污染和干燥条件下绝缘子的严重程度

Tumiran, M. Wahyudi, N. A. Setiawan, K. Pambudi, Dharma Saputra
{"title":"基于紫外线辐射的污染和干燥条件下绝缘子的严重程度","authors":"Tumiran, M. Wahyudi, N. A. Setiawan, K. Pambudi, Dharma Saputra","doi":"10.1109/SPIES48661.2020.9242998","DOIUrl":null,"url":null,"abstract":"In this study, the ultraviolet (UV) emitted by partial discharge which occurred on the insulator in polluted and dry conditions was investigated. The UV image and intensity were recorded for 1 minute per voltage variation per pollutant weight variation. The voltage stress was varied until the flashover occurred. The results showed that there was no consistent relationship between pollutant weight and those two UV emission parameters. In addition, the UV intensity consisted of maximum, minimum, and average values because it fluctuated during the recording. There were two UV image patterns that could be identified, namely the scattered points and the concentrated light (forming an area). The greatest the UV intensity, the highest deviation between the maximum and minimum values, and the largest concentrated light pattern were found during a critical condition.","PeriodicalId":244426,"journal":{"name":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","volume":"95 6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Severity Level of An Insulator in Polluted and Dry Conditions Based on Ultraviolet Emission\",\"authors\":\"Tumiran, M. Wahyudi, N. A. Setiawan, K. Pambudi, Dharma Saputra\",\"doi\":\"10.1109/SPIES48661.2020.9242998\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, the ultraviolet (UV) emitted by partial discharge which occurred on the insulator in polluted and dry conditions was investigated. The UV image and intensity were recorded for 1 minute per voltage variation per pollutant weight variation. The voltage stress was varied until the flashover occurred. The results showed that there was no consistent relationship between pollutant weight and those two UV emission parameters. In addition, the UV intensity consisted of maximum, minimum, and average values because it fluctuated during the recording. There were two UV image patterns that could be identified, namely the scattered points and the concentrated light (forming an area). The greatest the UV intensity, the highest deviation between the maximum and minimum values, and the largest concentrated light pattern were found during a critical condition.\",\"PeriodicalId\":244426,\"journal\":{\"name\":\"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)\",\"volume\":\"95 6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPIES48661.2020.9242998\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPIES48661.2020.9242998","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了在污染和干燥条件下绝缘子局部放电所产生的紫外线。每电压变化一次,每污染物重量变化一次,记录1分钟的紫外图像和强度。电压应力变化直至闪络发生。结果表明,污染物质量与这两个紫外辐射参数之间没有一致的关系。此外,由于紫外强度在记录过程中是波动的,因此紫外强度由最大值、最小值和平均值组成。可以识别出两种UV图像模式,即散射点和聚光(形成一个区域)。在临界条件下,紫外强度最大,最大值与最小值之间的偏差最大,聚光模式最大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Severity Level of An Insulator in Polluted and Dry Conditions Based on Ultraviolet Emission
In this study, the ultraviolet (UV) emitted by partial discharge which occurred on the insulator in polluted and dry conditions was investigated. The UV image and intensity were recorded for 1 minute per voltage variation per pollutant weight variation. The voltage stress was varied until the flashover occurred. The results showed that there was no consistent relationship between pollutant weight and those two UV emission parameters. In addition, the UV intensity consisted of maximum, minimum, and average values because it fluctuated during the recording. There were two UV image patterns that could be identified, namely the scattered points and the concentrated light (forming an area). The greatest the UV intensity, the highest deviation between the maximum and minimum values, and the largest concentrated light pattern were found during a critical condition.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信