{"title":"两种不同驱动条件下高频磁芯损耗的比较:正弦波电压和方波电压","authors":"D. Chen","doi":"10.1109/PESC.1978.7072358","DOIUrl":null,"url":null,"abstract":"It is observed that for the same peak flux density and the same operating frequency, the core loss induced by a square-wave voltage drive is less than the loss induced by a sinusoidal voltage drive, which is contrary to what one would normally anticipate. To the best of the author's knowledge, there Is no theory that predicts the loss difference observed.","PeriodicalId":363671,"journal":{"name":"1978 IEEE Power Electronics Specialists Conference","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1978-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"38","resultStr":"{\"title\":\"Comparisons of high frequency magnetic core losses under two different driving conditions: A sinusoidal voltage and a square-wave voltage\",\"authors\":\"D. Chen\",\"doi\":\"10.1109/PESC.1978.7072358\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is observed that for the same peak flux density and the same operating frequency, the core loss induced by a square-wave voltage drive is less than the loss induced by a sinusoidal voltage drive, which is contrary to what one would normally anticipate. To the best of the author's knowledge, there Is no theory that predicts the loss difference observed.\",\"PeriodicalId\":363671,\"journal\":{\"name\":\"1978 IEEE Power Electronics Specialists Conference\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1978-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"38\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1978 IEEE Power Electronics Specialists Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1978.7072358\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1978 IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1978.7072358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparisons of high frequency magnetic core losses under two different driving conditions: A sinusoidal voltage and a square-wave voltage
It is observed that for the same peak flux density and the same operating frequency, the core loss induced by a square-wave voltage drive is less than the loss induced by a sinusoidal voltage drive, which is contrary to what one would normally anticipate. To the best of the author's knowledge, there Is no theory that predicts the loss difference observed.