{"title":"直流偏置电磁电流互感器的特性","authors":"Chang-yun Li, Qingmin Li, Jinxia Yao, Min Liu","doi":"10.1109/SUPERGEN.2009.5348387","DOIUrl":null,"url":null,"abstract":"Both geomagnetically induced currents (GIC) and high voltage direct current (HVDC) projects using the earth as its path can cause direct current flowing in the ground. Direct current flux will be produced and has detrimental effects on power systems. Few references can be found about the effects of dc bias on the current transformer that is very important to both metering and protective aims. In this paper, the characteristics of electromagnetic CTs are discussed. At first, the primary current is determined, and a decaying dc offset is found which will affect the CT's dynamic performance. Then the CT's steady state and transient state characteristics with dc bias are researched. It shows that the turns ratio, direct current and some other parameters have effects on the CT's time-to-saturation which is important to protective engineers. EMTP simulation results confirm the validity of the results.","PeriodicalId":250585,"journal":{"name":"2009 International Conference on Sustainable Power Generation and Supply","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"The characteristics of electromagnetic current transformers with DC bias\",\"authors\":\"Chang-yun Li, Qingmin Li, Jinxia Yao, Min Liu\",\"doi\":\"10.1109/SUPERGEN.2009.5348387\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Both geomagnetically induced currents (GIC) and high voltage direct current (HVDC) projects using the earth as its path can cause direct current flowing in the ground. Direct current flux will be produced and has detrimental effects on power systems. Few references can be found about the effects of dc bias on the current transformer that is very important to both metering and protective aims. In this paper, the characteristics of electromagnetic CTs are discussed. At first, the primary current is determined, and a decaying dc offset is found which will affect the CT's dynamic performance. Then the CT's steady state and transient state characteristics with dc bias are researched. It shows that the turns ratio, direct current and some other parameters have effects on the CT's time-to-saturation which is important to protective engineers. EMTP simulation results confirm the validity of the results.\",\"PeriodicalId\":250585,\"journal\":{\"name\":\"2009 International Conference on Sustainable Power Generation and Supply\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Conference on Sustainable Power Generation and Supply\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SUPERGEN.2009.5348387\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Sustainable Power Generation and Supply","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SUPERGEN.2009.5348387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

地磁感应电流(GIC)和高压直流电(HVDC)项目都使用地球作为其路径,可以在地面上产生直流电。将产生直流磁通,并对电力系统产生不利影响。直流偏置对电流互感器的影响在计量和保护中都是非常重要的,但关于直流偏置对电流互感器影响的文献很少。本文讨论了电磁ct的特性。首先确定一次电流,找出影响电流互感器动态性能的衰减直流偏置。然后研究了直流偏置下电流互感器的稳态和瞬态特性。结果表明,匝比、直流电流等参数对电流互感器的饱和时间有一定的影响,对保护工程师具有重要意义。EMTP仿真结果验证了结果的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The characteristics of electromagnetic current transformers with DC bias
Both geomagnetically induced currents (GIC) and high voltage direct current (HVDC) projects using the earth as its path can cause direct current flowing in the ground. Direct current flux will be produced and has detrimental effects on power systems. Few references can be found about the effects of dc bias on the current transformer that is very important to both metering and protective aims. In this paper, the characteristics of electromagnetic CTs are discussed. At first, the primary current is determined, and a decaying dc offset is found which will affect the CT's dynamic performance. Then the CT's steady state and transient state characteristics with dc bias are researched. It shows that the turns ratio, direct current and some other parameters have effects on the CT's time-to-saturation which is important to protective engineers. EMTP simulation results confirm the validity of the results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信