心脏状态指示器和R-R间隔调节电路的设计

Sandhya Surendarraj, Palagani Yellappa, J. Choi
{"title":"心脏状态指示器和R-R间隔调节电路的设计","authors":"Sandhya Surendarraj, Palagani Yellappa, J. Choi","doi":"10.1109/ISOCC47750.2019.9027742","DOIUrl":null,"url":null,"abstract":"Despite great advancements in medical field, millions of people suffer from cardiac arrhythmia. The solutions for arrhythmia rely largely on early diagnosis and recognition, and therefore in this paper, we have designed a Cardiac Status Indicator and R-R interval (RRI) adjustment circuit to continuously indicate the status of ECG and generate anti-wave to normalize the abnormal waveform for next-generation cardiac pacemakers. The design accurately detects RRI's and for RRI lesser than 0.6s, an anti-wave is generated to suppress extra heartbeats against irregular heartbeats and on the other hand, for RRI greater than 1s, an anti-wave with extra beats is generated to normalize the heartbeat. The simulation is implemented in 0.18µm CMOS process and the circuits operate in the range of 0.9V to 1.8V.","PeriodicalId":113802,"journal":{"name":"2019 International SoC Design Conference (ISOCC)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of Cardiac Status Indicator and R-R Interval Adjustment Circuits\",\"authors\":\"Sandhya Surendarraj, Palagani Yellappa, J. Choi\",\"doi\":\"10.1109/ISOCC47750.2019.9027742\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Despite great advancements in medical field, millions of people suffer from cardiac arrhythmia. The solutions for arrhythmia rely largely on early diagnosis and recognition, and therefore in this paper, we have designed a Cardiac Status Indicator and R-R interval (RRI) adjustment circuit to continuously indicate the status of ECG and generate anti-wave to normalize the abnormal waveform for next-generation cardiac pacemakers. The design accurately detects RRI's and for RRI lesser than 0.6s, an anti-wave is generated to suppress extra heartbeats against irregular heartbeats and on the other hand, for RRI greater than 1s, an anti-wave with extra beats is generated to normalize the heartbeat. The simulation is implemented in 0.18µm CMOS process and the circuits operate in the range of 0.9V to 1.8V.\",\"PeriodicalId\":113802,\"journal\":{\"name\":\"2019 International SoC Design Conference (ISOCC)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International SoC Design Conference (ISOCC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISOCC47750.2019.9027742\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International SoC Design Conference (ISOCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISOCC47750.2019.9027742","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

尽管医学领域取得了很大的进步,但仍有数百万人患有心律失常。心律失常的解决很大程度上依赖于早期诊断和识别,因此本文设计了一种心脏状态指示器和R-R间隔(RRI)调节电路,用于连续指示ECG状态并产生反波,以规范下一代心脏起搏器的异常波形。该设计能够准确地检测RRI,当RRI小于0.6s时,产生反波抑制不规则心跳的额外心跳,当RRI大于1s时,产生额外心跳的反波使心跳正常化。仿真采用0.18µm CMOS工艺,电路工作在0.9V ~ 1.8V范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of Cardiac Status Indicator and R-R Interval Adjustment Circuits
Despite great advancements in medical field, millions of people suffer from cardiac arrhythmia. The solutions for arrhythmia rely largely on early diagnosis and recognition, and therefore in this paper, we have designed a Cardiac Status Indicator and R-R interval (RRI) adjustment circuit to continuously indicate the status of ECG and generate anti-wave to normalize the abnormal waveform for next-generation cardiac pacemakers. The design accurately detects RRI's and for RRI lesser than 0.6s, an anti-wave is generated to suppress extra heartbeats against irregular heartbeats and on the other hand, for RRI greater than 1s, an anti-wave with extra beats is generated to normalize the heartbeat. The simulation is implemented in 0.18µm CMOS process and the circuits operate in the range of 0.9V to 1.8V.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信