考虑多系统约束的分布式发电初始并网评估工具的开发

A. Kalankul, P. Jirapong, P. Saraisuwan, S. Premrudeepreechacharn
{"title":"考虑多系统约束的分布式发电初始并网评估工具的开发","authors":"A. Kalankul, P. Jirapong, P. Saraisuwan, S. Premrudeepreechacharn","doi":"10.1109/ICUEPES.2011.6497751","DOIUrl":null,"url":null,"abstract":"Assessment of distributed generation (DG) is a complicated task and it is a primary importance step in designing and planning of DG installation in distribution systems. The installation of DG units at non-appropriate location and sizing can result in an increasing in power losses and violations of system constraints. In this paper, a new DG assessment tool is developed for studying and evaluating DG installations in practical distribution systems. The assessment tool is developed by writing DIgSILENT Programming Language (DPL) script in DIgSILENT PowerFactory software. The tool is used for evaluating initial grid connection of DG, considering multi-system constraints-i.e. types of DG units, location, sizing, system loading, reverse power, voltage regulation, step voltage change, short circuit level, and energy losses. Two practical distribution systems including 9-bus system and 410-bus system from Provincial Electricity Authority (PEA) of Thailand are used as case studies. Test results show that the proposed assessment tool which relies on PEA regulation of DG connection can be used to evaluate the specified DG installation.","PeriodicalId":262691,"journal":{"name":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","volume":"130 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Development of distributed generation assessment tool considering multi-system constraints for evaluating initial grid connection\",\"authors\":\"A. Kalankul, P. Jirapong, P. Saraisuwan, S. Premrudeepreechacharn\",\"doi\":\"10.1109/ICUEPES.2011.6497751\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Assessment of distributed generation (DG) is a complicated task and it is a primary importance step in designing and planning of DG installation in distribution systems. The installation of DG units at non-appropriate location and sizing can result in an increasing in power losses and violations of system constraints. In this paper, a new DG assessment tool is developed for studying and evaluating DG installations in practical distribution systems. The assessment tool is developed by writing DIgSILENT Programming Language (DPL) script in DIgSILENT PowerFactory software. The tool is used for evaluating initial grid connection of DG, considering multi-system constraints-i.e. types of DG units, location, sizing, system loading, reverse power, voltage regulation, step voltage change, short circuit level, and energy losses. Two practical distribution systems including 9-bus system and 410-bus system from Provincial Electricity Authority (PEA) of Thailand are used as case studies. Test results show that the proposed assessment tool which relies on PEA regulation of DG connection can be used to evaluate the specified DG installation.\",\"PeriodicalId\":262691,\"journal\":{\"name\":\"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)\",\"volume\":\"130 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICUEPES.2011.6497751\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference & Utility Exhibition on Power and Energy Systems: Issues and Prospects for Asia (ICUE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICUEPES.2011.6497751","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

分布式发电系统的评估是一项复杂的任务,是分布式发电系统设计和规划的重要环节。DG装置安装在不合适的位置和尺寸可能会导致功率损耗增加,并违反系统约束。本文开发了一种新的DG评估工具,用于研究和评估实际配电系统中的DG安装。该评估工具是在DIgSILENT PowerFactory软件中编写DIgSILENT编程语言(DPL)脚本开发的。该工具用于评估DG的初始并网,考虑了多系统约束,即。DG单元的类型、位置、尺寸、系统负载、反向功率、电压调节、阶跃电压变化、短路电平和能量损失。以泰国省电力局(PEA)的9总线系统和410总线系统两种实际配电系统为例进行了研究。试验结果表明,所提出的评估工具依赖于DG连接的PEA调节,可用于对指定DG安装进行评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of distributed generation assessment tool considering multi-system constraints for evaluating initial grid connection
Assessment of distributed generation (DG) is a complicated task and it is a primary importance step in designing and planning of DG installation in distribution systems. The installation of DG units at non-appropriate location and sizing can result in an increasing in power losses and violations of system constraints. In this paper, a new DG assessment tool is developed for studying and evaluating DG installations in practical distribution systems. The assessment tool is developed by writing DIgSILENT Programming Language (DPL) script in DIgSILENT PowerFactory software. The tool is used for evaluating initial grid connection of DG, considering multi-system constraints-i.e. types of DG units, location, sizing, system loading, reverse power, voltage regulation, step voltage change, short circuit level, and energy losses. Two practical distribution systems including 9-bus system and 410-bus system from Provincial Electricity Authority (PEA) of Thailand are used as case studies. Test results show that the proposed assessment tool which relies on PEA regulation of DG connection can be used to evaluate the specified DG installation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信