东北-阿格拉高压直流工程近距离运行混合电场暂态分析

Brajagopal Datta, S. Chatterjee
{"title":"东北-阿格拉高压直流工程近距离运行混合电场暂态分析","authors":"Brajagopal Datta, S. Chatterjee","doi":"10.1109/CATCON47128.2019.CN0034","DOIUrl":null,"url":null,"abstract":"Close Proximity Operation of HVAC and HVDC transmission line is the recent trend for increase of power transmission capacity. Need for same is becoming vital day by day due to ever increasing power demand. Erection of HVAC lines has a requirement of high right of way (ROW) as compared to the HVDC lines. Also recent past has witnessed constraint in availability of ROW for many projects of Indian Power Grid. Raise in transmission voltage level of HVDC from Power Grid Corporation of India Limited (PGCIL) and its suitability to decentralized non-conventional grids has led to addition of many upcoming HVDC projects with the already existing ones. So the need of analysis for electric field distribution under this type of hybrid transmission corridor is necessary to meet the standards of engineering design, exposure limits to living beings and environmental protection. The present work shows a two dimensional modelling approach for estimation of hybrid electric field at ground surface with impulse excitation. A practical case of hybrid transmission corridor so formed in Northeast Agra HVDC project of PGCIL has been taken for this case. Effects of both standard and non-standard impulse waveform has been modelled and analysis of its effect on hybrid electric field is presented.","PeriodicalId":183797,"journal":{"name":"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transient Analysis for Hybrid Electric Field in close proximity HVAC-HVDC operation of Northeast – Agra HVDC project\",\"authors\":\"Brajagopal Datta, S. Chatterjee\",\"doi\":\"10.1109/CATCON47128.2019.CN0034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Close Proximity Operation of HVAC and HVDC transmission line is the recent trend for increase of power transmission capacity. Need for same is becoming vital day by day due to ever increasing power demand. Erection of HVAC lines has a requirement of high right of way (ROW) as compared to the HVDC lines. Also recent past has witnessed constraint in availability of ROW for many projects of Indian Power Grid. Raise in transmission voltage level of HVDC from Power Grid Corporation of India Limited (PGCIL) and its suitability to decentralized non-conventional grids has led to addition of many upcoming HVDC projects with the already existing ones. So the need of analysis for electric field distribution under this type of hybrid transmission corridor is necessary to meet the standards of engineering design, exposure limits to living beings and environmental protection. The present work shows a two dimensional modelling approach for estimation of hybrid electric field at ground surface with impulse excitation. A practical case of hybrid transmission corridor so formed in Northeast Agra HVDC project of PGCIL has been taken for this case. Effects of both standard and non-standard impulse waveform has been modelled and analysis of its effect on hybrid electric field is presented.\",\"PeriodicalId\":183797,\"journal\":{\"name\":\"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CATCON47128.2019.CN0034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CATCON47128.2019.CN0034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

暖通、直流输电线路近距离运行是近年来提高输电容量的趋势。由于不断增长的电力需求,对相同的需求日益重要。与高压直流线路相比,暖通空调线路的安装有较高的通行权(ROW)要求。最近也见证了印度电网许多项目的ROW可用性受到限制。印度电网有限公司(PGCIL)的高压直流输电电压水平的提高及其对分散式非常规电网的适用性,导致许多即将到来的高压直流项目在现有项目的基础上增加。因此,为了满足工程设计、生物暴露限值和环境保护的要求,有必要对这种混合输电走廊下的电场分布进行分析。本文提出了一种估算脉冲激励下地表混合电场的二维建模方法。以PGCIL阿格拉东北直流工程为例,分析了由此形成的混合输电走廊的实际情况。对标准和非标准脉冲波形的影响进行了建模,并分析了其对混合电场的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transient Analysis for Hybrid Electric Field in close proximity HVAC-HVDC operation of Northeast – Agra HVDC project
Close Proximity Operation of HVAC and HVDC transmission line is the recent trend for increase of power transmission capacity. Need for same is becoming vital day by day due to ever increasing power demand. Erection of HVAC lines has a requirement of high right of way (ROW) as compared to the HVDC lines. Also recent past has witnessed constraint in availability of ROW for many projects of Indian Power Grid. Raise in transmission voltage level of HVDC from Power Grid Corporation of India Limited (PGCIL) and its suitability to decentralized non-conventional grids has led to addition of many upcoming HVDC projects with the already existing ones. So the need of analysis for electric field distribution under this type of hybrid transmission corridor is necessary to meet the standards of engineering design, exposure limits to living beings and environmental protection. The present work shows a two dimensional modelling approach for estimation of hybrid electric field at ground surface with impulse excitation. A practical case of hybrid transmission corridor so formed in Northeast Agra HVDC project of PGCIL has been taken for this case. Effects of both standard and non-standard impulse waveform has been modelled and analysis of its effect on hybrid electric field is presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信