{"title":"基于2SPV-BES的微电网同步与电能质量改善","authors":"S. Roy, Farheen Chishti, Bhim Singh, B. K. Panigrahi","doi":"10.1109/SeFeT55524.2022.9908880","DOIUrl":null,"url":null,"abstract":"This paper deals with the control and synchronization of double-stage solar photovoltaic (2SPV)-battery energy storage (BES) based three phase microgrid. The modified damped second order generalized integrator (MDSOGI) current control algorithm is used to feed power to the grid and at the same time it is used to provide phase angle and frequency estimation for the purpose of synchronization. MDSOGI is a modified version of the damped-SOGI structure, where frequency is estimated by integrating a frequency locked-loop (FLL) algorithm that utilizes the quadrature shifted components of the DSOGI structure. It has better power quality (PQ) performance, enhanced load balancing ability, effective harmonic mitigation property due to the band-pass-filter type phase response of the SOGI structure and is robust during frequency deviations. MDSOGI is used to extract the active and reactive fundamental weight components for generation of reference grid currents. Thus, the current control also meets the reactive power demand at common coupling point (CCP). In islanded mode of operation, voltage control mode is utilized and the MDSOGIFLL with the help of phase angle regulator is used to generate local frequency. This system is simulated in SIMULINK/Matlab R2020b and is subjected to various dynamic conditions for validating the satisfactory performance. Total harmonic distortion (THD) is found well within the IEEE-519 standard.","PeriodicalId":262863,"journal":{"name":"2022 IEEE 2nd International Conference on Sustainable Energy and Future Electric Transportation (SeFeT)","volume":"os-28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Synchronization and Power Quality Improvement of 2SPV-BES Based Microgrid\",\"authors\":\"S. Roy, Farheen Chishti, Bhim Singh, B. K. Panigrahi\",\"doi\":\"10.1109/SeFeT55524.2022.9908880\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the control and synchronization of double-stage solar photovoltaic (2SPV)-battery energy storage (BES) based three phase microgrid. The modified damped second order generalized integrator (MDSOGI) current control algorithm is used to feed power to the grid and at the same time it is used to provide phase angle and frequency estimation for the purpose of synchronization. MDSOGI is a modified version of the damped-SOGI structure, where frequency is estimated by integrating a frequency locked-loop (FLL) algorithm that utilizes the quadrature shifted components of the DSOGI structure. It has better power quality (PQ) performance, enhanced load balancing ability, effective harmonic mitigation property due to the band-pass-filter type phase response of the SOGI structure and is robust during frequency deviations. MDSOGI is used to extract the active and reactive fundamental weight components for generation of reference grid currents. Thus, the current control also meets the reactive power demand at common coupling point (CCP). In islanded mode of operation, voltage control mode is utilized and the MDSOGIFLL with the help of phase angle regulator is used to generate local frequency. This system is simulated in SIMULINK/Matlab R2020b and is subjected to various dynamic conditions for validating the satisfactory performance. Total harmonic distortion (THD) is found well within the IEEE-519 standard.\",\"PeriodicalId\":262863,\"journal\":{\"name\":\"2022 IEEE 2nd International Conference on Sustainable Energy and Future Electric Transportation (SeFeT)\",\"volume\":\"os-28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 2nd International Conference on Sustainable Energy and Future Electric Transportation (SeFeT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SeFeT55524.2022.9908880\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 2nd International Conference on Sustainable Energy and Future Electric Transportation (SeFeT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SeFeT55524.2022.9908880","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了基于双级太阳能光伏(2SPV)-电池储能(BES)三相微电网的控制与同步问题。采用改进的阻尼二阶广义积分器(MDSOGI)电流控制算法向电网供电,同时提供相角和频率估计以实现同步。MDSOGI是阻尼式sogi结构的改进版本,其中通过集成频率锁环(FLL)算法来估计频率,该算法利用DSOGI结构的正交位移分量。由于SOGI结构的带通滤波器型相位响应,它具有更好的电能质量(PQ)性能,增强的负载平衡能力,有效的谐波抑制性能,并且在频率偏差时具有鲁棒性。MDSOGI用于提取有功和无功基权分量,用于生成参考网格电流。因此,电流控制也能满足共联轴点(CCP)的无功需求。孤岛运行时,采用电压控制方式,利用MDSOGIFLL配合相角调节器产生局域频率。在SIMULINK/Matlab R2020b中对系统进行了仿真,并在各种动态条件下进行了仿真,验证了系统的良好性能。总谐波失真(THD)完全符合IEEE-519标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Synchronization and Power Quality Improvement of 2SPV-BES Based Microgrid
This paper deals with the control and synchronization of double-stage solar photovoltaic (2SPV)-battery energy storage (BES) based three phase microgrid. The modified damped second order generalized integrator (MDSOGI) current control algorithm is used to feed power to the grid and at the same time it is used to provide phase angle and frequency estimation for the purpose of synchronization. MDSOGI is a modified version of the damped-SOGI structure, where frequency is estimated by integrating a frequency locked-loop (FLL) algorithm that utilizes the quadrature shifted components of the DSOGI structure. It has better power quality (PQ) performance, enhanced load balancing ability, effective harmonic mitigation property due to the band-pass-filter type phase response of the SOGI structure and is robust during frequency deviations. MDSOGI is used to extract the active and reactive fundamental weight components for generation of reference grid currents. Thus, the current control also meets the reactive power demand at common coupling point (CCP). In islanded mode of operation, voltage control mode is utilized and the MDSOGIFLL with the help of phase angle regulator is used to generate local frequency. This system is simulated in SIMULINK/Matlab R2020b and is subjected to various dynamic conditions for validating the satisfactory performance. Total harmonic distortion (THD) is found well within the IEEE-519 standard.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信