冰渐进应力法:400kv线路和设备绝缘子全尺寸试验的重复性及试验结果的应用

I. Gutman, K. Halsan, T. Ohnstad, D. Hiibinette
{"title":"冰渐进应力法:400kv线路和设备绝缘子全尺寸试验的重复性及试验结果的应用","authors":"I. Gutman, K. Halsan, T. Ohnstad, D. Hiibinette","doi":"10.1109/ELINSL.2004.1380695","DOIUrl":null,"url":null,"abstract":"The ice progressive stress (IPS) method fulfils international requirements and has been included by IEEE in the position paper of accepted ice test procedures Farzanch, M. et al. (2003). The present paper analyses the repeatability of the test results of 400 kV voltage class line cap-and-pin/long rod insulators and circuit breakers. The results of the tests of nine different types of full-scale insulator strings and three different types of full-scale T-formed circuit breakers are analyzed. The analysis of the repeatability showed that the results are repeatable in terms of the variation of the different test parameters. The statistical test results in the form of 50% flashover voltage and standard deviation are completely applicable for the statistical dimensioning (availability calculations) using specially developed computer program. Examples are presented in the paper.","PeriodicalId":342687,"journal":{"name":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Ice progressive stress method: repeatability during full-scale testing of 400 kV line and apparatus insulators and application of the test results\",\"authors\":\"I. Gutman, K. Halsan, T. Ohnstad, D. Hiibinette\",\"doi\":\"10.1109/ELINSL.2004.1380695\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The ice progressive stress (IPS) method fulfils international requirements and has been included by IEEE in the position paper of accepted ice test procedures Farzanch, M. et al. (2003). The present paper analyses the repeatability of the test results of 400 kV voltage class line cap-and-pin/long rod insulators and circuit breakers. The results of the tests of nine different types of full-scale insulator strings and three different types of full-scale T-formed circuit breakers are analyzed. The analysis of the repeatability showed that the results are repeatable in terms of the variation of the different test parameters. The statistical test results in the form of 50% flashover voltage and standard deviation are completely applicable for the statistical dimensioning (availability calculations) using specially developed computer program. Examples are presented in the paper.\",\"PeriodicalId\":342687,\"journal\":{\"name\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2004.1380695\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2004.1380695","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

冰的渐进应力(IPS)方法符合国际要求,并已被IEEE纳入公认的冰试验程序Farzanch, M. et al.(2003)的立场文件中。本文分析了400kv电压等级线路cap- pin/long - rod绝缘子和断路器试验结果的重复性。分析了9种全尺寸绝缘子串和3种全尺寸t型断路器的试验结果。可重复性分析表明,在不同试验参数的变化情况下,结果是可重复的。50%闪络电压和标准偏差形式的统计试验结果完全适用于专门开发的计算机程序的统计量纲(可用性计算)。文中给出了实例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ice progressive stress method: repeatability during full-scale testing of 400 kV line and apparatus insulators and application of the test results
The ice progressive stress (IPS) method fulfils international requirements and has been included by IEEE in the position paper of accepted ice test procedures Farzanch, M. et al. (2003). The present paper analyses the repeatability of the test results of 400 kV voltage class line cap-and-pin/long rod insulators and circuit breakers. The results of the tests of nine different types of full-scale insulator strings and three different types of full-scale T-formed circuit breakers are analyzed. The analysis of the repeatability showed that the results are repeatable in terms of the variation of the different test parameters. The statistical test results in the form of 50% flashover voltage and standard deviation are completely applicable for the statistical dimensioning (availability calculations) using specially developed computer program. Examples are presented in the paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信