{"title":"突发事件下STATCOM最优配置的分析方法","authors":"Bazilah Ismail, N. A. Abdul Wahab, M. Lutfi Othman, M. A. Mohd Radzi, Kanendra Naidu Vijayakumar, Muhammad Mat Naain","doi":"10.1109/SPIES48661.2020.9243128","DOIUrl":null,"url":null,"abstract":"Electrical power utilities nowadays are facing various challenges with emerging technologies that leads to increase in demand on electrical power. Due to the aging grid infrastructure, existing power transmission networks are forced to operate at near critical point which could cause tripping in transmission lines and potentially lead to cascading outages and blackout. During this point, voltage at some buses drop below the lower voltage limit and the system power loss is significantly high. Constructing new power system networks or expanding existing networks is a must to accommodate the impact of ever-increasing demand. However, this consumes a lot of time and money. This can be alleviated by integrating Flexible Alternating Current Transmission System (FACTS) devices in the existing transmission system. In order to ensure investment feasibility, the location of FACTS devices in the network is essential. In this study, several analytical approaches using loss sensitivity factor (LSF), real power performance indicator (PI), voltage profile index (VPI) and power loss index (PLI) is carried out to examine the optimal location of Static Synchronous Compensator (STATCOM) in the power system. The proposed analytical approaches were examined using the IEEE 14 bus and IEEE 30 bus benchmark test systems in DigSILENT PowerFactory 18.","PeriodicalId":244426,"journal":{"name":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Analytical Approaches on Optimal Placement of STATCOM Under Contingency Occasions\",\"authors\":\"Bazilah Ismail, N. A. Abdul Wahab, M. Lutfi Othman, M. A. Mohd Radzi, Kanendra Naidu Vijayakumar, Muhammad Mat Naain\",\"doi\":\"10.1109/SPIES48661.2020.9243128\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrical power utilities nowadays are facing various challenges with emerging technologies that leads to increase in demand on electrical power. Due to the aging grid infrastructure, existing power transmission networks are forced to operate at near critical point which could cause tripping in transmission lines and potentially lead to cascading outages and blackout. During this point, voltage at some buses drop below the lower voltage limit and the system power loss is significantly high. Constructing new power system networks or expanding existing networks is a must to accommodate the impact of ever-increasing demand. However, this consumes a lot of time and money. This can be alleviated by integrating Flexible Alternating Current Transmission System (FACTS) devices in the existing transmission system. In order to ensure investment feasibility, the location of FACTS devices in the network is essential. In this study, several analytical approaches using loss sensitivity factor (LSF), real power performance indicator (PI), voltage profile index (VPI) and power loss index (PLI) is carried out to examine the optimal location of Static Synchronous Compensator (STATCOM) in the power system. The proposed analytical approaches were examined using the IEEE 14 bus and IEEE 30 bus benchmark test systems in DigSILENT PowerFactory 18.\",\"PeriodicalId\":244426,\"journal\":{\"name\":\"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPIES48661.2020.9243128\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPIES48661.2020.9243128","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

随着新兴技术的出现,电力公司面临着各种各样的挑战,导致电力需求的增加。由于电网基础设施老化,现有输电网络被迫在接近临界点的地方运行,这可能导致输电线路跳闸,并可能导致级联停电和停电。在此期间,一些母线的电压降至电压下限以下,系统功率损耗明显高。建设新的电力系统网络或扩建现有网络是必须的,以适应不断增长的需求的影响。然而,这消耗了大量的时间和金钱。这可以通过在现有的传输系统中集成柔性交流传输系统(FACTS)设备来缓解。为了保证投资的可行性,FACTS设备在网络中的位置至关重要。本文采用损耗敏感系数(LSF)、实际功率性能指标(PI)、电压分布指数(VPI)和功率损耗指数(PLI)等分析方法,考察了静态同步补偿器(STATCOM)在电力系统中的最优位置。使用DigSILENT PowerFactory 18中的IEEE 14总线和IEEE 30总线基准测试系统对所提出的分析方法进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analytical Approaches on Optimal Placement of STATCOM Under Contingency Occasions
Electrical power utilities nowadays are facing various challenges with emerging technologies that leads to increase in demand on electrical power. Due to the aging grid infrastructure, existing power transmission networks are forced to operate at near critical point which could cause tripping in transmission lines and potentially lead to cascading outages and blackout. During this point, voltage at some buses drop below the lower voltage limit and the system power loss is significantly high. Constructing new power system networks or expanding existing networks is a must to accommodate the impact of ever-increasing demand. However, this consumes a lot of time and money. This can be alleviated by integrating Flexible Alternating Current Transmission System (FACTS) devices in the existing transmission system. In order to ensure investment feasibility, the location of FACTS devices in the network is essential. In this study, several analytical approaches using loss sensitivity factor (LSF), real power performance indicator (PI), voltage profile index (VPI) and power loss index (PLI) is carried out to examine the optimal location of Static Synchronous Compensator (STATCOM) in the power system. The proposed analytical approaches were examined using the IEEE 14 bus and IEEE 30 bus benchmark test systems in DigSILENT PowerFactory 18.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信