{"title":"基于s变换的电力系统脉冲暂态检测、分类与定位","authors":"M. Jaya Bharata Reddy, D. Mohanta","doi":"10.1109/EEEIC.2010.5489944","DOIUrl":null,"url":null,"abstract":"Power quality issues have been of a great concern in recent years due to extensive use of power electronic devices and non-linear loads in electrical power system. In order to monitor electrical power quality disturbance, short time discrete Fourier transform (STFT) is most often used. But in case of non-stationary signals, STFT does not track the signal dynamics properly due to limitations of a fixed window width chosen a priori. By using wavelet transform, disturbances in electrical power system can only be detected and localized, but for sake of classification, standard multi-resolution analysis or other classification techniques must be used. This paper presents a new approach for power quality analysis along with classification using a modified wavelet transform, known as S-transform. Case studies for detection and classification several complex power quality disturbances for impulsive transients using S-transform have been corroborated in this paper and the results contained in this paper validate superiority of S-transform over wavelet transform.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"136 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Detection, classification and localization of power system impulsive transients using S-transform\",\"authors\":\"M. Jaya Bharata Reddy, D. Mohanta\",\"doi\":\"10.1109/EEEIC.2010.5489944\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power quality issues have been of a great concern in recent years due to extensive use of power electronic devices and non-linear loads in electrical power system. In order to monitor electrical power quality disturbance, short time discrete Fourier transform (STFT) is most often used. But in case of non-stationary signals, STFT does not track the signal dynamics properly due to limitations of a fixed window width chosen a priori. By using wavelet transform, disturbances in electrical power system can only be detected and localized, but for sake of classification, standard multi-resolution analysis or other classification techniques must be used. This paper presents a new approach for power quality analysis along with classification using a modified wavelet transform, known as S-transform. Case studies for detection and classification several complex power quality disturbances for impulsive transients using S-transform have been corroborated in this paper and the results contained in this paper validate superiority of S-transform over wavelet transform.\",\"PeriodicalId\":197298,\"journal\":{\"name\":\"2010 9th International Conference on Environment and Electrical Engineering\",\"volume\":\"136 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 9th International Conference on Environment and Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEEIC.2010.5489944\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 9th International Conference on Environment and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2010.5489944","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Detection, classification and localization of power system impulsive transients using S-transform
Power quality issues have been of a great concern in recent years due to extensive use of power electronic devices and non-linear loads in electrical power system. In order to monitor electrical power quality disturbance, short time discrete Fourier transform (STFT) is most often used. But in case of non-stationary signals, STFT does not track the signal dynamics properly due to limitations of a fixed window width chosen a priori. By using wavelet transform, disturbances in electrical power system can only be detected and localized, but for sake of classification, standard multi-resolution analysis or other classification techniques must be used. This paper presents a new approach for power quality analysis along with classification using a modified wavelet transform, known as S-transform. Case studies for detection and classification several complex power quality disturbances for impulsive transients using S-transform have been corroborated in this paper and the results contained in this paper validate superiority of S-transform over wavelet transform.