{"title":"公共配电系统中无功电源的优化配置以改善电能质量","authors":"B. Neagu, G. Georgescu","doi":"10.1109/OPTIM.2012.6231856","DOIUrl":null,"url":null,"abstract":"The important changes that occurred during the last years regarding the shifting of the consumption share from high voltage (HV) to medium voltage (MV) and low voltage (LV), the diversification and the increase of the number of non-linear and/or non-symmetrical consumers, the removal of the reactive power sources (shunt capacitor banks - SCB) that contained polychlorinated biphenyl compounds (PBC) placed in the electricity repartition and distribution systems (ERDS), etc., led to the appearance of some complex problems related to the maintaining of the quality of electricity delivered to the consumers through ERDS. Using multi-criteria optimization processes, the paper presents mathematical models, algorithms and computation software intended for the best management of the reactive power sources, both in the nodes of the electricity repartition systems (ERS) and the electricity distribution systems (EDS). Thus, either traditional algorithms or algorithms based on possibilities offered by artificial intelligence are used.","PeriodicalId":382406,"journal":{"name":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"The optimization of reactive power sources placement in public repartition and distribution systems for power quality improvement\",\"authors\":\"B. Neagu, G. Georgescu\",\"doi\":\"10.1109/OPTIM.2012.6231856\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The important changes that occurred during the last years regarding the shifting of the consumption share from high voltage (HV) to medium voltage (MV) and low voltage (LV), the diversification and the increase of the number of non-linear and/or non-symmetrical consumers, the removal of the reactive power sources (shunt capacitor banks - SCB) that contained polychlorinated biphenyl compounds (PBC) placed in the electricity repartition and distribution systems (ERDS), etc., led to the appearance of some complex problems related to the maintaining of the quality of electricity delivered to the consumers through ERDS. Using multi-criteria optimization processes, the paper presents mathematical models, algorithms and computation software intended for the best management of the reactive power sources, both in the nodes of the electricity repartition systems (ERS) and the electricity distribution systems (EDS). Thus, either traditional algorithms or algorithms based on possibilities offered by artificial intelligence are used.\",\"PeriodicalId\":382406,\"journal\":{\"name\":\"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OPTIM.2012.6231856\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OPTIM.2012.6231856","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

在过去几年中发生的重要变化,包括消费份额从高压(HV)转移到中压(MV)和低压(LV),非线性和/或非对称消费者的多样化和数量的增加,在电力再分配和配电系统(ERDS)中含有多氯联苯化合物(PBC)的无功电源(并联电容器组- SCB)的移除等。导致一些复杂的问题出现,这些问题与如何维持透过电力供应系统提供给用户的电力质素有关。本文利用多准则优化过程,提出了用于电力再分配系统(ERS)和配电系统(EDS)节点无功电源最佳管理的数学模型、算法和计算软件。因此,要么使用传统算法,要么使用基于人工智能提供的可能性的算法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The optimization of reactive power sources placement in public repartition and distribution systems for power quality improvement
The important changes that occurred during the last years regarding the shifting of the consumption share from high voltage (HV) to medium voltage (MV) and low voltage (LV), the diversification and the increase of the number of non-linear and/or non-symmetrical consumers, the removal of the reactive power sources (shunt capacitor banks - SCB) that contained polychlorinated biphenyl compounds (PBC) placed in the electricity repartition and distribution systems (ERDS), etc., led to the appearance of some complex problems related to the maintaining of the quality of electricity delivered to the consumers through ERDS. Using multi-criteria optimization processes, the paper presents mathematical models, algorithms and computation software intended for the best management of the reactive power sources, both in the nodes of the electricity repartition systems (ERS) and the electricity distribution systems (EDS). Thus, either traditional algorithms or algorithms based on possibilities offered by artificial intelligence are used.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信