{"title":"电容电极传感器:设计与测试","authors":"Salami Ifedapo Abdullahi, M. H. Habaebi, N. Malik","doi":"10.1109/ICCCE.2018.8539287","DOIUrl":null,"url":null,"abstract":"This paper proposed an alternative method of measuring water level using a Printed Circuit Board(PCB). The design of the electrode water level sensor went through circuit sketching, printing of sketch on PCB and etching. The signal conditioning circuit board was fabricated using a donut board and other electrical components. Experimentation was carried on the fabricated electrode sensor and the capacitance and current for each electrode finger was measured using digital multimeter and LCR meter. The multiple correlation of the water level, measured current and measured capacitance produced a value of 0.921 withP-values less than 0.05 showing the strength of the data obtained from the test conducted. The electrode water level sensor has proven to be consistent and reliable under normal working condition.","PeriodicalId":260264,"journal":{"name":"2018 7th International Conference on Computer and Communication Engineering (ICCCE)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Capacitive Electrode Sensor:Design and Testing\",\"authors\":\"Salami Ifedapo Abdullahi, M. H. Habaebi, N. Malik\",\"doi\":\"10.1109/ICCCE.2018.8539287\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposed an alternative method of measuring water level using a Printed Circuit Board(PCB). The design of the electrode water level sensor went through circuit sketching, printing of sketch on PCB and etching. The signal conditioning circuit board was fabricated using a donut board and other electrical components. Experimentation was carried on the fabricated electrode sensor and the capacitance and current for each electrode finger was measured using digital multimeter and LCR meter. The multiple correlation of the water level, measured current and measured capacitance produced a value of 0.921 withP-values less than 0.05 showing the strength of the data obtained from the test conducted. The electrode water level sensor has proven to be consistent and reliable under normal working condition.\",\"PeriodicalId\":260264,\"journal\":{\"name\":\"2018 7th International Conference on Computer and Communication Engineering (ICCCE)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 7th International Conference on Computer and Communication Engineering (ICCCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCCE.2018.8539287\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 7th International Conference on Computer and Communication Engineering (ICCCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCCE.2018.8539287","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
This paper proposed an alternative method of measuring water level using a Printed Circuit Board(PCB). The design of the electrode water level sensor went through circuit sketching, printing of sketch on PCB and etching. The signal conditioning circuit board was fabricated using a donut board and other electrical components. Experimentation was carried on the fabricated electrode sensor and the capacitance and current for each electrode finger was measured using digital multimeter and LCR meter. The multiple correlation of the water level, measured current and measured capacitance produced a value of 0.921 withP-values less than 0.05 showing the strength of the data obtained from the test conducted. The electrode water level sensor has proven to be consistent and reliable under normal working condition.