载荷对临床应用的商用WBV平台机械性能影响的案例研究

F. Orsini, A. Scorza, C. Foti, A. Rossi, M. Sollini, S. Conforto, Simone Ranaldi, F. Vurchio, S. Sciuto, Fabio Fuiano, F. Botta
{"title":"载荷对临床应用的商用WBV平台机械性能影响的案例研究","authors":"F. Orsini, A. Scorza, C. Foti, A. Rossi, M. Sollini, S. Conforto, Simone Ranaldi, F. Vurchio, S. Sciuto, Fabio Fuiano, F. Botta","doi":"10.1109/MeMeA49120.2020.9137146","DOIUrl":null,"url":null,"abstract":"The use of whole body vibration (WBV) platforms in neuromuscular studies has grown in the last years, especially for the interest of the technique in fields such as rehabilitation and sport training. Different studies have dealt with the correlation between biological effect and frequency or acceleration magnitude, but little has been told regarding the influence of the applied weight on the performances of WBV plates. In this work a commercial WBV platform, has been tested with different loads measuring the accelerations of the footboard. The results show that the system has a reduction of the mean acceleration at high loads, although the variability of the system response at fixed load is noticeable. The high variability is then an actual and very challenging issue and an in-depth characterization of the WBV plates must be done before making reproducible studies on the biological effect of vibrations in clinical applications.","PeriodicalId":152478,"journal":{"name":"2020 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A case study about the load effect on the mechanical performances in a commercial WBV platform for clinical applications\",\"authors\":\"F. Orsini, A. Scorza, C. Foti, A. Rossi, M. Sollini, S. Conforto, Simone Ranaldi, F. Vurchio, S. Sciuto, Fabio Fuiano, F. Botta\",\"doi\":\"10.1109/MeMeA49120.2020.9137146\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The use of whole body vibration (WBV) platforms in neuromuscular studies has grown in the last years, especially for the interest of the technique in fields such as rehabilitation and sport training. Different studies have dealt with the correlation between biological effect and frequency or acceleration magnitude, but little has been told regarding the influence of the applied weight on the performances of WBV plates. In this work a commercial WBV platform, has been tested with different loads measuring the accelerations of the footboard. The results show that the system has a reduction of the mean acceleration at high loads, although the variability of the system response at fixed load is noticeable. The high variability is then an actual and very challenging issue and an in-depth characterization of the WBV plates must be done before making reproducible studies on the biological effect of vibrations in clinical applications.\",\"PeriodicalId\":152478,\"journal\":{\"name\":\"2020 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA49120.2020.9137146\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA49120.2020.9137146","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

近年来,全身振动(WBV)平台在神经肌肉研究中的应用越来越广泛,特别是在康复和运动训练等领域。不同的研究已经处理了生物效应与频率或加速度大小之间的关系,但很少有人告诉关于施加重量对WBV板性能的影响。在这项工作中,商用WBV平台在不同负载下进行了测试,测量了踏板的加速度。结果表明,系统在高负载下的平均加速度有所降低,但在固定负载下系统响应的可变性是明显的。因此,高可变性是一个实际且非常具有挑战性的问题,在对振动在临床应用中的生物效应进行可重复的研究之前,必须对WBV板进行深入的表征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A case study about the load effect on the mechanical performances in a commercial WBV platform for clinical applications
The use of whole body vibration (WBV) platforms in neuromuscular studies has grown in the last years, especially for the interest of the technique in fields such as rehabilitation and sport training. Different studies have dealt with the correlation between biological effect and frequency or acceleration magnitude, but little has been told regarding the influence of the applied weight on the performances of WBV plates. In this work a commercial WBV platform, has been tested with different loads measuring the accelerations of the footboard. The results show that the system has a reduction of the mean acceleration at high loads, although the variability of the system response at fixed load is noticeable. The high variability is then an actual and very challenging issue and an in-depth characterization of the WBV plates must be done before making reproducible studies on the biological effect of vibrations in clinical applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信