Y. Morita, M. Honda, T. Kuraoka, Y. Fukasawa, Y. Mitoma, H. Yoshizumi, H. Hayashiya
{"title":"东京站光伏局部平滑效应分析","authors":"Y. Morita, M. Honda, T. Kuraoka, Y. Fukasawa, Y. Mitoma, H. Yoshizumi, H. Hayashiya","doi":"10.1109/ICRERA.2012.6477266","DOIUrl":null,"url":null,"abstract":"We analyzed the local smoothing effect in view of time window for the PV system on Tokyo station. The smoothing effect differs according to the range of time windows. In cases of fine day, the result revealed that it is effective to smooth the fluctuation range of electric power output from PV within ten seconds.","PeriodicalId":239142,"journal":{"name":"2012 International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Analysis of local smoothing effect on the PV on Tokyo station\",\"authors\":\"Y. Morita, M. Honda, T. Kuraoka, Y. Fukasawa, Y. Mitoma, H. Yoshizumi, H. Hayashiya\",\"doi\":\"10.1109/ICRERA.2012.6477266\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We analyzed the local smoothing effect in view of time window for the PV system on Tokyo station. The smoothing effect differs according to the range of time windows. In cases of fine day, the result revealed that it is effective to smooth the fluctuation range of electric power output from PV within ten seconds.\",\"PeriodicalId\":239142,\"journal\":{\"name\":\"2012 International Conference on Renewable Energy Research and Applications (ICRERA)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Renewable Energy Research and Applications (ICRERA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICRERA.2012.6477266\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Renewable Energy Research and Applications (ICRERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRERA.2012.6477266","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of local smoothing effect on the PV on Tokyo station
We analyzed the local smoothing effect in view of time window for the PV system on Tokyo station. The smoothing effect differs according to the range of time windows. In cases of fine day, the result revealed that it is effective to smooth the fluctuation range of electric power output from PV within ten seconds.