一种宽带CMOS电流驱动器,用于输出直流调节的生物阻抗应用

L. Constantinou, A. Demosthenous
{"title":"一种宽带CMOS电流驱动器,用于输出直流调节的生物阻抗应用","authors":"L. Constantinou, A. Demosthenous","doi":"10.1109/BioCAS.2013.6679637","DOIUrl":null,"url":null,"abstract":"Bioimpedance measurements are performed in a wide range of frequencies (100Hz to 1MHz) as physiological tissue information is scattered throughout this frequency band. Wideband current drivers with high output impedance are essential to maintain high injected current accuracy over a wide range of load impedances. The purpose of the work presented in this paper is the design methodology of a fully integrated, wideband current driver for bioimpedance measurement systems. The circuit has been designed and simulated in a standard CMOS 0.6-um technology delivering currents of up to 2mA pk-pk operating from a ±6V power supply. Results show an output current phase delay of -2.43° at 1MHz and an output impedance of 8MΩ at 100Hz reducing to 1.08MΩ at 1MHz.","PeriodicalId":344317,"journal":{"name":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A wideband CMOS current driver for bioimpedance applications with output DC regulation\",\"authors\":\"L. Constantinou, A. Demosthenous\",\"doi\":\"10.1109/BioCAS.2013.6679637\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Bioimpedance measurements are performed in a wide range of frequencies (100Hz to 1MHz) as physiological tissue information is scattered throughout this frequency band. Wideband current drivers with high output impedance are essential to maintain high injected current accuracy over a wide range of load impedances. The purpose of the work presented in this paper is the design methodology of a fully integrated, wideband current driver for bioimpedance measurement systems. The circuit has been designed and simulated in a standard CMOS 0.6-um technology delivering currents of up to 2mA pk-pk operating from a ±6V power supply. Results show an output current phase delay of -2.43° at 1MHz and an output impedance of 8MΩ at 100Hz reducing to 1.08MΩ at 1MHz.\",\"PeriodicalId\":344317,\"journal\":{\"name\":\"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BioCAS.2013.6679637\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BioCAS.2013.6679637","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

生物阻抗测量在很宽的频率范围内(100Hz至1MHz)进行,因为生理组织信息分散在整个频带中。具有高输出阻抗的宽带电流驱动器对于在很宽的负载阻抗范围内保持高注入电流精度至关重要。本文提出的工作目的是为生物阻抗测量系统提供一个完全集成的宽带电流驱动器的设计方法。该电路采用标准CMOS 0.6 um技术进行设计和仿真,在±6V电源下工作,电流高达2mA pk-pk。结果表明,在1MHz时输出电流相位延迟为-2.43°,在100Hz时输出阻抗为8MΩ,在1MHz时降低到1.08MΩ。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A wideband CMOS current driver for bioimpedance applications with output DC regulation
Bioimpedance measurements are performed in a wide range of frequencies (100Hz to 1MHz) as physiological tissue information is scattered throughout this frequency band. Wideband current drivers with high output impedance are essential to maintain high injected current accuracy over a wide range of load impedances. The purpose of the work presented in this paper is the design methodology of a fully integrated, wideband current driver for bioimpedance measurement systems. The circuit has been designed and simulated in a standard CMOS 0.6-um technology delivering currents of up to 2mA pk-pk operating from a ±6V power supply. Results show an output current phase delay of -2.43° at 1MHz and an output impedance of 8MΩ at 100Hz reducing to 1.08MΩ at 1MHz.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信