触觉反馈装置插针模拟力v/s实验力

I. Fazal, M. N. Karsiti
{"title":"触觉反馈装置插针模拟力v/s实验力","authors":"I. Fazal, M. N. Karsiti","doi":"10.1109/SCORED.2009.5443248","DOIUrl":null,"url":null,"abstract":"This paper presents needle insertion forces for haptic feedback device in soft tissue. The force information from needle insertions is being measured by the sensor. The force feedback produced by the device is used in robot-assisted percutaneous therapies. The objective of the work reported here is to design a device for reality-based data. Insertion force data was collected on chicken skin and meat. The needle insertion force is modeled in three parts; force due to capsule stiffness, friction and cutting. The data from model is compared with real time force data. From the simulation and experimental results, it is found out that the error between measured and modeled force converges to zero.","PeriodicalId":443287,"journal":{"name":"2009 IEEE Student Conference on Research and Development (SCOReD)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Needle insertion simulation forces v/s experimental forces for haptic feedback device\",\"authors\":\"I. Fazal, M. N. Karsiti\",\"doi\":\"10.1109/SCORED.2009.5443248\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents needle insertion forces for haptic feedback device in soft tissue. The force information from needle insertions is being measured by the sensor. The force feedback produced by the device is used in robot-assisted percutaneous therapies. The objective of the work reported here is to design a device for reality-based data. Insertion force data was collected on chicken skin and meat. The needle insertion force is modeled in three parts; force due to capsule stiffness, friction and cutting. The data from model is compared with real time force data. From the simulation and experimental results, it is found out that the error between measured and modeled force converges to zero.\",\"PeriodicalId\":443287,\"journal\":{\"name\":\"2009 IEEE Student Conference on Research and Development (SCOReD)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE Student Conference on Research and Development (SCOReD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SCORED.2009.5443248\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Student Conference on Research and Development (SCOReD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCORED.2009.5443248","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了用于软组织触觉反馈装置的针插入力。传感器正在测量针插入产生的力信息。该装置产生的力反馈用于机器人辅助的经皮治疗。这里报告的工作目标是设计一个基于现实的数据的设备。在鸡皮和鸡肉上收集插入力数据。针插入力建模分为三部分;力由于包膜刚度,摩擦和切割。将模型得到的数据与实时受力数据进行了比较。仿真和实验结果表明,实测力与模型力的误差趋近于零。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Needle insertion simulation forces v/s experimental forces for haptic feedback device
This paper presents needle insertion forces for haptic feedback device in soft tissue. The force information from needle insertions is being measured by the sensor. The force feedback produced by the device is used in robot-assisted percutaneous therapies. The objective of the work reported here is to design a device for reality-based data. Insertion force data was collected on chicken skin and meat. The needle insertion force is modeled in three parts; force due to capsule stiffness, friction and cutting. The data from model is compared with real time force data. From the simulation and experimental results, it is found out that the error between measured and modeled force converges to zero.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信