{"title":"单次接触砷的异速生长及其在提取0%致死水平中的应用","authors":"A. Guenda","doi":"10.2495/EHR090331","DOIUrl":null,"url":null,"abstract":"The relation between the exposure response to toxic gases, such as arsine, and the exposure time is almost non linear in a large domain of time. This non linear behaviour is especially visible when closer to the 0% lethal level, or closer to the 100% lethal level. An allometric behaviour has been displayed between the linear extrapolated exposure time corresponding to the 0% lethal level and the time corresponding to the medium of the linearity domain at a given concentration. Different methods have been used when displaying this allometry in order to ensure validity and reliability.","PeriodicalId":370021,"journal":{"name":"WIT Transactions on Biomedicine and Health","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Allometry Displayed In The Case Of Response ToSingle Exposure To Arsine And Its Use In TheExtraction Of The 0% Lethal Level\",\"authors\":\"A. Guenda\",\"doi\":\"10.2495/EHR090331\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The relation between the exposure response to toxic gases, such as arsine, and the exposure time is almost non linear in a large domain of time. This non linear behaviour is especially visible when closer to the 0% lethal level, or closer to the 100% lethal level. An allometric behaviour has been displayed between the linear extrapolated exposure time corresponding to the 0% lethal level and the time corresponding to the medium of the linearity domain at a given concentration. Different methods have been used when displaying this allometry in order to ensure validity and reliability.\",\"PeriodicalId\":370021,\"journal\":{\"name\":\"WIT Transactions on Biomedicine and Health\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"WIT Transactions on Biomedicine and Health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2495/EHR090331\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"WIT Transactions on Biomedicine and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2495/EHR090331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Allometry Displayed In The Case Of Response ToSingle Exposure To Arsine And Its Use In TheExtraction Of The 0% Lethal Level
The relation between the exposure response to toxic gases, such as arsine, and the exposure time is almost non linear in a large domain of time. This non linear behaviour is especially visible when closer to the 0% lethal level, or closer to the 100% lethal level. An allometric behaviour has been displayed between the linear extrapolated exposure time corresponding to the 0% lethal level and the time corresponding to the medium of the linearity domain at a given concentration. Different methods have been used when displaying this allometry in order to ensure validity and reliability.