Dexycu®在白内障摘除术中的持续眼内残留:一个病例系列

Ryan T. Wallace, Annika M. Hansen, John A. Musser VI, Anthony P. Mai, Craig J. Chaya
{"title":"Dexycu®在白内障摘除术中的持续眼内残留:一个病例系列","authors":"Ryan T. Wallace, Annika M. Hansen, John A. Musser VI, Anthony P. Mai, Craig J. Chaya","doi":"10.9734/or/2022/v17i330258","DOIUrl":null,"url":null,"abstract":"Purpose: The objective of this article is to report 8 cases of persistent IOL residue associated with the use of Dexycu® in the context of cataract surgery and then to subsequently describe each patients clinical course. \nObservations and Presentation: Between 2020-2021, persistent residue was noted in 8 eyes of 7 patients who received Dexycu® implants after cataract surgery. The residue was identified an average of 1.63 months after surgery (range 0.20-4.23). A subsequent procedure removed the residue from the intraocular lens; the average time to the follow-up procedure after surgery was 4.71 months (range 1.90-11.20). \nConclusions and Importance: The Bausch and Lomb intraocular lenses seem to be predisposed to a Dexycu® persistent opacification, however correlation does not equate with causation. This article documents cases of persistent IOL residue with the use of Dexycu® and the MX60 lenses and its toric varieties. Further evaluation is necessary to elucidate the mechanism and risk factors for this occurrence.","PeriodicalId":287685,"journal":{"name":"Ophthalmology Research: An International Journal","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Persistent Intraocular Residue with the Use of Dexycu® in Cataract Extraction: A Case Series\",\"authors\":\"Ryan T. Wallace, Annika M. Hansen, John A. Musser VI, Anthony P. Mai, Craig J. Chaya\",\"doi\":\"10.9734/or/2022/v17i330258\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: The objective of this article is to report 8 cases of persistent IOL residue associated with the use of Dexycu® in the context of cataract surgery and then to subsequently describe each patients clinical course. \\nObservations and Presentation: Between 2020-2021, persistent residue was noted in 8 eyes of 7 patients who received Dexycu® implants after cataract surgery. The residue was identified an average of 1.63 months after surgery (range 0.20-4.23). A subsequent procedure removed the residue from the intraocular lens; the average time to the follow-up procedure after surgery was 4.71 months (range 1.90-11.20). \\nConclusions and Importance: The Bausch and Lomb intraocular lenses seem to be predisposed to a Dexycu® persistent opacification, however correlation does not equate with causation. This article documents cases of persistent IOL residue with the use of Dexycu® and the MX60 lenses and its toric varieties. Further evaluation is necessary to elucidate the mechanism and risk factors for this occurrence.\",\"PeriodicalId\":287685,\"journal\":{\"name\":\"Ophthalmology Research: An International Journal\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmology Research: An International Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9734/or/2022/v17i330258\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology Research: An International Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/or/2022/v17i330258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本文的目的是报告8例白内障手术中使用Dexycu®导致的持续性IOL残留,并随后描述每位患者的临床病程。观察和报告:在2020-2021年间,7例白内障手术后接受Dexycu®植入物的患者的8只眼睛中发现了持久性残留物。术后平均1.63个月发现残留(范围0.20-4.23)。随后的手术切除了人工晶状体的残留物;术后平均随访时间为4.71个月(1.90 ~ 11.20个月)。结论和重要性:鲍氏和隆氏人工晶状体似乎易发生Dexycu®持续性混浊,但相关性不等于因果关系。本文记录了使用Dexycu®和MX60透镜及其环形品种的持久性IOL残留的病例。需要进一步的评估来阐明这种发生的机制和危险因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Persistent Intraocular Residue with the Use of Dexycu® in Cataract Extraction: A Case Series
Purpose: The objective of this article is to report 8 cases of persistent IOL residue associated with the use of Dexycu® in the context of cataract surgery and then to subsequently describe each patients clinical course. Observations and Presentation: Between 2020-2021, persistent residue was noted in 8 eyes of 7 patients who received Dexycu® implants after cataract surgery. The residue was identified an average of 1.63 months after surgery (range 0.20-4.23). A subsequent procedure removed the residue from the intraocular lens; the average time to the follow-up procedure after surgery was 4.71 months (range 1.90-11.20). Conclusions and Importance: The Bausch and Lomb intraocular lenses seem to be predisposed to a Dexycu® persistent opacification, however correlation does not equate with causation. This article documents cases of persistent IOL residue with the use of Dexycu® and the MX60 lenses and its toric varieties. Further evaluation is necessary to elucidate the mechanism and risk factors for this occurrence.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信