氧化锡气体传感器阵列冗余分析

M. Shi, B. Guo, A. Bermak
{"title":"氧化锡气体传感器阵列冗余分析","authors":"M. Shi, B. Guo, A. Bermak","doi":"10.1109/DELTA.2006.75","DOIUrl":null,"url":null,"abstract":"Using gas sensor array is widely accepted to overcome the non-selectivity of a single sensor. For tin oxide gas sensors, the size of array can’t be very large due to the limited number of doping materials. In this paper, our experimental results shows that duplication of the sensors doped by the same metal is an efficient way to improve the selectivity of the array due to the fabrication mismatch of the sensor chip. We also compare two methods of reducing the dimension of gas patterns: removing the sensors providing redundant information in the array and using principle component analysis (PCA). The experimental results shows that when the number of components is too large PCA can be a useful tool to reduce the data dimension.","PeriodicalId":439448,"journal":{"name":"Third IEEE International Workshop on Electronic Design, Test and Applications (DELTA'06)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Redundancy Analysis for Tin Oxide Gas Sensor Array\",\"authors\":\"M. Shi, B. Guo, A. Bermak\",\"doi\":\"10.1109/DELTA.2006.75\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Using gas sensor array is widely accepted to overcome the non-selectivity of a single sensor. For tin oxide gas sensors, the size of array can’t be very large due to the limited number of doping materials. In this paper, our experimental results shows that duplication of the sensors doped by the same metal is an efficient way to improve the selectivity of the array due to the fabrication mismatch of the sensor chip. We also compare two methods of reducing the dimension of gas patterns: removing the sensors providing redundant information in the array and using principle component analysis (PCA). The experimental results shows that when the number of components is too large PCA can be a useful tool to reduce the data dimension.\",\"PeriodicalId\":439448,\"journal\":{\"name\":\"Third IEEE International Workshop on Electronic Design, Test and Applications (DELTA'06)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Third IEEE International Workshop on Electronic Design, Test and Applications (DELTA'06)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DELTA.2006.75\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Third IEEE International Workshop on Electronic Design, Test and Applications (DELTA'06)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DELTA.2006.75","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

为了克服单个传感器的非选择性,采用气体传感器阵列已被广泛接受。对于氧化锡气体传感器,由于掺杂材料的数量有限,阵列的尺寸不能很大。在本文中,我们的实验结果表明,由于传感器芯片的制造不匹配,由相同金属掺杂的传感器的重复是提高阵列选择性的有效方法。我们还比较了两种降低气体模式维数的方法:去除阵列中提供冗余信息的传感器和使用主成分分析(PCA)。实验结果表明,当成分数过大时,主成分分析是一种有效的降维工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Redundancy Analysis for Tin Oxide Gas Sensor Array
Using gas sensor array is widely accepted to overcome the non-selectivity of a single sensor. For tin oxide gas sensors, the size of array can’t be very large due to the limited number of doping materials. In this paper, our experimental results shows that duplication of the sensors doped by the same metal is an efficient way to improve the selectivity of the array due to the fabrication mismatch of the sensor chip. We also compare two methods of reducing the dimension of gas patterns: removing the sensors providing redundant information in the array and using principle component analysis (PCA). The experimental results shows that when the number of components is too large PCA can be a useful tool to reduce the data dimension.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信